Two new two-step immunoassays for free thyroxin evaluated: solid-phase radioimmunoassay and time-resolved fluoroimmunoassay

Author:

Nuutila P1,Koskinen P1,Irjala K1,Linko L1,Kaihola H L1,Eskola J U1,Erkkola R1,Seppälä P1,Viikari J1

Affiliation:

1. Department of Internal Medicine, University Central Hospital, Turku, Finland

Abstract

Abstract We measured concentrations of free thyroxin (FT4) in serum by using two new two-step FT4 assays--a solid-phase two-step radioimmunoassay. Spectria, and a time-resolved fluoroimmunoassay. Delfia--and compared the results with those by a two-step FT4 assay (RIA-gnost), a one-step FT4 analog assay (Amerlex-M), and FT4 measured after equilibrium dialysis. The new FT4 assays classified 30 hypothyroid and 43 hyperthyroid patients (untreated) well. In 138 patients with nonthyroidal illness (NTI) and in late pregnancy (n = 36), fewer subnormal FT4 values were reported by Spectria (P less than 0.001), Delfia (P less than 0.001), and RIA-gnost (P less than 0.01) than by Amerlex-M. The results of the Spectria and Delfia methods correlated with the results of the dialysis method (r = 0.76) in NTI patients and pregnancy, and were in better agreement with the clinical state than was FT4 by Amerlex-M. The FT4 values by Amerlex-M, but not by other methods, correlated with albumin concentration. We conclude that these new two-step methods present good alternatives for FT4 analysis.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3