Author:
Zerwekh J E,Drake E,Gregory J,Griffith D,Hofmann A F,Menon M,Pak C Y
Abstract
Abstract
To assess how well results by different methods for urinary oxalate determinations agree with each other in a clinical setting, we compared six different assays: Hodgkinson and Williams (Clin Chim Acta 36:127-132, 1972), enzymatic, modified Hodgkinson and Williams, gas chromatography, ion chromatography, and "high-pressure" liquid chromatography. For the entire group of samples, the mean value by each method agreed relatively closely, although the enzymatic procedure produced a somewhat higher value. All six methods had large coefficients of variation within (8-58%) and between (15-88%) assays. In addition, analytical recovery by most assays was more than 100% of the added oxalate. Analytical recovery of 10 micrograms of oxalate added per milliliter of urine specimen ranged from 86 to 237%; for 20 micrograms/mL it was 83 to 320%. Thus for the six methods evaluated, no single method appeared to be superior to the others.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry, medical,Clinical Biochemistry
Cited by
34 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献