Accurate and precise isotope dilution mass spectrometry method for determining glucose in whole blood

Author:

Hannestad Ulf,Lundblad Arne1

Affiliation:

1. Department of Clinical Chemistry, University Hospital, S-581 85 Linköping, Sweden

Abstract

Abstract An accurate and precise method to determine glucose concentration in whole blood is presented. The method, based on isotope dilution gas chromatography–mass spectrometry (ID GC-MS), was developed to be used as a Reference Method for determining glucose concentration in capillary or venous whole blood. Blood samples and standards are pipetted manually with “microcap” micropipettes, which makes it possible to collect samples even at the patient’s bedside. Glucose is quantified as its aldononitrile pentaacetate. [13C6]Glucose is used as an internal standard. Assay of Seronorm and Pathonorm L and H controls by ID GC-MS gave within-run CVs of 0.66%, 0.96%, and 0.92%, respectively. For whole blood with glucose concentrations in the low, normal, and high ranges, the within-run CVs were 1.27%, 0.91%, and 0.78%, respectively. The between-run CV for glucose calculated from 36 separate single analyses of Seronorm was 1.44%. In an accuracy assessment test of the HemoCue blood glucose analyzer, 140 capillary blood samples were measured in parallel after split-sampling. For all samples the HemoCue analyzer results had a mean bias of +2.0% compared with the ID GC-MS results.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3