Determination of Carbohydrate-deficient Transferrin Using Capillary Zone Electrophoresis

Author:

Wuyts Birgitte1,Delanghe Joris R1,Kasvosve Ishmael2,Wauters Annick3,Neels Hugo4,Janssens Jacques5

Affiliation:

1. Department of Clinical Chemistry, Ghent University Hospital, De Pintelaan 185, B9000 Ghent, Belgium

2. Departments of Medicine and Chemical Pathology, Medical School, The University of Zimbabwe, Avondale, Harare, Zimbabwe

3. Department of Clinical Chemistry, Middelheim Hospital, Lindendreef 1, B2020 Antwerp, Belgium

4. Department of Clinical Chemistry, AZ Stuivenberg, Lange Beeldekensstraat 267, B2060 Antwerp, Belgium

5. Analis SA, 14 Rue Dewez, B5000 Namur, Belgium

Abstract

AbstractBackground: Current methods for carbohydrate-deficient transferrin (CDT) often suffer from low precision, complexity, or risk of false positives attributable to genetic variants. In this study, a new capillary zone electrophoresis (CZE) method for CDT was developed.Methods: CZE was performed on a P/ACE 5000 using fused-silica capillaries [50 μm (i.d.) × 47 cm] and the CEOFIX CDT buffer system with addition of 50 μL of anti-C3c and 10 μL of anti-hemoglobin. Native sera were loaded by high-pressure injection for 3 s, separated at 28 kV over 12 min, and monitored at 214 nm.Results: CDT was completely resolved by differences in migration times (di-trisialotransferrin, 9.86 ± 0.05 min; monosialotransferrin, 9.72 ± 0.05 min; asialotransferrin, 9.52 ± 0.04 min), with a CV of 0.15%. The number of theoretical plates was 312 000 ± 21 000 for the mono- and 199 000 ± 6500 for the di-trisialylated transferrin. Genetic CB and CD variants showed prominent peaks with migration times of 10.12 ± 0.06 and 9.89 ± 0.03 min, respectively, and the carbohydrate-deficient glycoprotein syndrome could be detected, excluding false-positive results. CZE results (as a percentage; y) correlated with the Axis %CDT TIATM (x) values by Deming regression analysis: y = 1.92x − 7.29; r = 0.89. CDT values in 130 healthy nonalcoholics were determined. The 2.5th and 97.5th percentiles were 1.84% and 6.79%.Conclusions: CZE without sample pretreatment can determine CDT with good precision, allows detection of variants, and correlates with ion-exchange chromatography.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3