Urine Albumin Measurements in Clinical Diagnostics

Author:

Seegmiller Jesse C1ORCID,Bachmann Lorin M2

Affiliation:

1. Department of Laboratory Medicine and Pathology, University of Minnesota , Minneapolis, MN , United States

2. Department of Pathology, Virginia Commonwealth University , Richmond, VA , United States

Abstract

Abstract Background Measurement of urine albumin is critical for diagnosis, risk classification, and monitoring of chronic kidney disease (CKD). Guidelines recommend clinical decision cutoffs for the urine albumin-to-creatinine ratio (ACR) of 30 and 300 mg/g (3 and 30 mg/mmol). However, differences among manufacturers’ routine urine albumin measurement procedures have been found to exceed 40%, suggesting CKD diagnosis and risk classification may vary depending upon the specific measurement procedure implemented in the laboratory. Content This review discusses urine albumin pathophysiology and clinical practice guideline recommendations for CKD. The review also provides recommendations for urine specimen collection and storage, and results reporting for the ACR. Recent advances in measurement techniques and development of reference systems intended to facilitate standardization of urine albumin measurements are reviewed. Summary Urine albumin is an important measurement procedure used for diagnosis, risk classification, and management of CKD. Urine albumin results should be reported as the ACR using quantitative measurement procedures. Random urine collections used for albuminuria screening should be followed by confirmation with first morning void collections to reduce variation and increase diagnostic accuracy for urine albumin measurement. Most measurement procedures utilize immunoturbidimetric or immunonephelometric techniques. However, results vary significantly among measurement procedures, potentially resulting in differences in classification or risk assessment for CKD. The National Institute for Standards and Technology (NIST) and other laboratories are developing reference systems, including liquid chromatography–tandem mass spectrometry candidate reference measurement procedures and reference materials, to enable standardization of routine measurement procedures.

Publisher

Oxford University Press (OUP)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3