Point-of-Care Time-resolved Immunofluorometric Assay for Human Pregnancy-associated Plasma Protein A: Use in First-Trimester Screening for Down Syndrome

Author:

Qin Qiu-Ping1,Christiansen Michael2,Pettersson Kim1

Affiliation:

1. Department of Biotechnology, University of Turku, Tykistökatu 6, 20520 Turku, Finland

2. Department of Clinical Biochemistry, Statens Seruminstitut, Artillerivej 5, DK-2300 S Copenhagen, Denmark

Abstract

AbstractBackground: Screening for Down syndrome in the first trimester by a combination of fetal nuchal translucency thickness and maternal serum pregnancy-associated plasma protein A (PAPP-A) and free β-human chorionic gonadotropin has been shown to be effective and efficient. We aimed to develop a fast point-of-care assay that could be placed in one-stop clinics for the measurement of PAPP-A.Methods: We developed a two-site, one-step assay that uses two monoclonal antibodies (mAbs) to PAPP-A, based on a dry-reagent, all-in-one immunoassay concept with a stable fluorescent lanthanide chelate and time-resolved fluorometry. One antibody (mAb 10E1) was biotinylated, and the other (mAb 234-5) was europium-labeled, both via the ε-amino groups of surface lysine residues. The assay was performed on an AIO immunoanalyzer at 36 °C in single, streptavidin-coated microtitration wells that contained the dry reagents. PAPP-A, either in free or complexed form, was detected by the antibodies used.Results: The assay procedure required 20 min and used 10 μL of sample. The calibration curve was linear from 5 to 10 000 mIU/L. The detection limit was 0.5 mIU/L. Intra- and interassay imprecision (CV) was ≤4.3% and 8.3%, respectively, for whole blood, plasma, or serum samples. Recovery was 93–96% for serum, 95–108% for heparin-derived whole blood, and 98–103% for heparin-derived plasma. Parallelism was observed in all three matrices. Results correlated [slope = 0.85 (confidence interval, 0.82–0.87); intercept = −33 (confidence interval, −58 to −9); Sy|x = 85 mIU/L; r = 0.991; n = 100] with those obtained by a Delfia assay. Heparin did not affect the assay, but EDTA markedly reduced PAPP-A values. PAPP-A was stable at 4 °C for at least 18 days in serum and for 8 days in heparin-derived whole blood or plasma.Conclusions: The present assay appears suited for use in one-stop clinics for screening for Down syndrome in the first trimester, with results available within 1 h.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3