Duration of Detectable Methamphetamine and Amphetamine Excretion in Urine after Controlled Oral Administration of Methamphetamine to Humans

Author:

Oyler Jonathan M1,Cone Edward J2,Joseph Robert E3,Moolchan Eric T1,Huestis Marilyn A1

Affiliation:

1. Chemistry and Drug Metabolism Section, Intramural Research Program, National Institute on Drug Abuse, 5500 Nathan Shock Dr., Baltimore, MD 21224

2. ConeChem Research, LLC, 441 Fairtree Dr., Severna Park, MD 21146

3. Amgen Inc., One Amgen Center Dr., Thousand Oaks, CA 91320

Abstract

AbstractBackground: Confirmation of a workplace drug test requires urinary methamphetamine (MAMP) and amphetamine (AMP) concentrations ≥500 and 200 μg/L, respectively, but cutoffs at half those values (250/100 μg/L) have been proposed. We determined the urinary excretion of MAMP after oral ingestion and examined the effect of using lower cutoffs on detection of exposure.Methods: Volunteers (n = 8) ingested four 10-mg doses of MAMP · HCl daily over 7 days, and five of them ingested four 20-mg doses 4 weeks later. After ingestion, the volunteers collected all urine specimens for 2 weeks. After solid-phase extraction, MAMP and AMP were measured by gas chromatography–positive chemical ionization mass spectrometry with dual silyl derivatization.Results: MAMP and AMP were generally detected in the first or second void (0.7–11.3 h) collected after drug administration, with concentrations of 82–1827 and 12–180 μg/L, respectively. Peak MAMP concentrations (1871–6004 μg/L) after single doses occurred within 1.5–60 h. MAMP ≥500 μg/L was first detected in the first or second void (1–11 h) at 524-1871 μg/L. Lowering the MAMP cutoff to 250 μg/L changed the initial detection time little. AMP ≥200 μg/L was first detected in the 2nd–13th (7–20 h) post-administration voids. At a cutoff of 100 μg/L, AMP was first confirmed in the second to eighth void (4–13 h). Reducing the cutoff to 250/100 μg/L extended terminal MAMP detection by up to 24 h, increased total detection time by up to 34 h, and increased the total number of positive specimens by 48%.Conclusions: At the lower cutoff, initial detection times are earlier, detection windows are longer, and confirmation rates are increased. Elimination of the AMP requirement would increase detection rates and allow earlier detection.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3