Direct Serum Total Iron-binding Capacity Assay Suitable for Automated Analyzers

Author:

Siek Gordon1,Lawlor Joseph1,Pelczar Donna1,Sane Meena1,Musto Joseph12

Affiliation:

1. Reference Diagnostics, Inc., 19 Crosby Dr., Suite 30, Bedford, MA 01730

2. Diagnostic Laboratory Medicine, Inc., 14 Crosby Dr., Bedford, MA 01730

Abstract

Abstract Background: Present methods for measuring serum total iron-binding capacity (TIBC) involve manipulation of samples or performance of two assays on each sample. We developed a direct automated assay (DTIBC) for TIBC. Methods: We added to serum a saturating amount of iron bound to an excess of chelating dye at a low pH, recorded a blank reading that represented the sum of the saturating amount of iron plus the serum iron, and then added a strong neutral pH buffer. The decrease in absorbance (as transferrin extracts iron from the iron-dye complex) is directly proportional to the TIBC. TIBC values for 125 patients were determined by DTIBC, alumina column TIBC (AC), magnetic particle TIBC (MTIBC), and the UIBC method (UIBC) on Roche COBAS FARA and Mira chemistry analyzers. In a separate study, TIBC values for 128 patients were determined on an Olympus AU400 by the DTIBC and the MTIBC methods. Results: Methods comparisons on the COBAS analyzers yielded the following results: DTIBC = 1.05(MTIBC) − 1.0 μmol/L (r = 0.987; Sy|x = 2.6 μmol/L); DTIBC = 1.07(AC) − 1.0 μmol/L (r = 0.982; Sy|x = 3.0 μmol/L); and DTIBC = 1.14(UIBC) + 3.4 μmol/L (r = 0.982; Sy|x = 3.0 μmol/L). A similar correlation study using the Olympus AU400 yielded DTIBC = 1.00(MTIBC) − 0.1 μmol/L (r = 0.983; Sy|x = 2.7 μmol/L). The assay was linear from 12.5 to 125 μmol/L (70–700 μg/dL) TIBC on the COBAS FARA. Within- and between-run imprecision (CV) was ≤4.8% at two concentrations. Plasma samples were unsuitable for the method. No interference was seen with common interferants other than ascorbate, deferoxamine, and ferrous sulfate, and only at concentrations well above normal. Conclusion: The new DTIBC assay is suitable for routine use in clinical laboratories and may improve the quality of iron metabolism studies.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3