Capillary and Microchip Electrophoresis for Rapid Detection of Known Mutations by Combining Allele-specific DNA Amplification with Heteroduplex Analysis

Author:

Tian Huijun1,Brody Lawrence C2,Fan Saijun3,Huang Zhili4,Landers James P45

Affiliation:

1. Department of Chemistry, University of Pittsburgh, Pittsburgh, PA 15260

2. Genetics and Molecular Biology Branch, National Human Genome Research Institute, National Institutes of Health, Bethesda, MD 20892

3. Department of Radiation Oncology, Long Island Jewish Medical Center, Albert Einstein College of Medicine, New Hyde Park, NY 11040

4. Department of Chemistry, University of Virginia, Charlottesville, VA 22901

5. Department of Pathology, University of Virginia Medical Center, Charlottesville, VA 22908

Abstract

Abstract Background: Detection of mutations by gel electrophoresis and allele-specific amplification by PCR (AS-PCR) is not easily scaled to accommodate a large number of samples. Alternative electrophoretic formats, such as capillary electrophoresis (CE) and microchip electrophoresis, may provide powerful platforms for simple, fast, automated, and high-throughput mutation detection after allele-specific amplification. Methods: DNA samples heterozygous for four mutations (185delAG, 5382insC, 3867G→T, and 6174delT) in BRCA1 and BRCA2, and homozygous for one mutation (5382insC) in BRCA1 and two mutations (16delAA and 822delG) in PTEN were chosen as the model system to evaluate the capillary and microchip electrophoresis methods. To detect each mutation, three primers, of which one was labeled with the fluorescent dye 6-carboxyfluorescein and one was the allele-specific primer (mutation-specific primer), were used to amplify the DNA fragments in the range of 130–320 bp. AS-PCR was combined with heteroduplex (HD) analysis, where the DNA fragments obtained by AS-PCR were analyzed with the conditions developed for CE-based HD analysis (using a fluorocarbon-coated capillary and hydroxyethylcellulose). The CE conditions were transferred into the microchip electrophoresis format. Results: Three genotypes, homozygous wild type, homozygous mutant, and heterozygous mutant, could be identified by CE-based AS-PCR-HD analysis after 10–25 min of analysis time. Using the conditions optimized with CE, we translated the AS-PCR-HD analysis mutation detection method to the microchip electrophoresis format. The detection of three heterozygous mutations (insertion, deletion, and substitution) in BRCA1 could be accomplished in 180 s or less. Conclusions: It is possible to develop a CE-based method that exploits both AS-PCR and HD analysis for detecting specific mutations. Fast separation and the capacity for automated operation create the potential for developing a powerful electrophoresis-based mutation detection system. Fabrication of multichannel microchip platforms may enable mutation detection with high throughput.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3