Influence of Adsorption and Deproteination on Potential Free Thyroxine Reference Methods

Author:

Holm Steen S1,Andreasen Lisbeth1,Hansen Steen H2,Faber Jens3,Staun-Olsen Poul1

Affiliation:

1. Department of Clinical Biochemistry, Holbæk Hospital, 4300 Holbæk, Denmark

2. Department of Analytical and Pharmaceutical Chemistry, Royal Danish School of Pharmacy, 2100 Copenhagen, Denmark

3. Department of Endocrinology E and Clinical Chemistry, Frederiksberg Hospital, 2000 Frederiksberg, Denmark

Abstract

Abstract Background: There is a need for consensus concerning reference methods to be used for calibration of commercial free-thyroxine (FT4) assays. Methods: Three different potential reference techniques were investigated for adsorption of T4 to membrane materials, including any in vitro solid surfaces to which T4 might adsorb, and for efficient separation of the T4-binding proteins from the free hormone fraction. We compared ultrafiltration with different commercial ultrafiltration units, ultrafiltration by dialysis tubing, equilibrium dialysis, and ultracentrifugation. We measured the adsorption to membranes and materials with l-[125I]T4. Separation efficiency was determined by measuring the T4-binding protein albumin in the ultrafiltrate and the dialysate as well as in the supernatant from the ultracentrifugation with a double-antibody sandwich ELISA technique. Results: We found a constant relationship between the amount of T4 adsorbed to the dialysis or ultrafiltration membranes/materials and the initial T4 concentration in HEPES buffer (protein-free medium). T4 was considerably less adsorbed from serum than from HEPES buffer (P <0.001). Serum T4 was less adsorbed upon ultracentrifugation than during dialysis and ultrafiltration (P <0.001). It was difficult to completely separate FT4 from the binding proteins by ultrafiltration and ultracentrifugation. Separation by ultrafiltration depended on the material used. Conclusions: No investigated separation technique provides technically and theoretically correct separation of the free fraction of T4 from the protein-bound fraction. Equilibrium dialysis seems to be the least compromised.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3