Author:
Al-Dujaili E A,Forrest G C,Edwards C R,Landon J
Abstract
Abstract
We compared conventional charcoal separation of antibody-bound and free antigen with a novel method involving magnetizable particles containing charcoal. The magnetizable charcoal separation method was as effective as the conventional method for a wide range of radioimmunoassays, including those for several steroids and small polypeptide hormones. In a detailed comparison of conventional vs. magnetizable charcoal for radioimmunoassay of aldosterone, the magnetizable charcoal had several advantages: it did not require prior coating with dextran or protein, varied less with time and temperature, required no centrifugation, and took less time for separation. The correlation of results obtained with magnetizable and conventional charcoal separation was excellent (n = 89, r = 0.98, p less than 0.001), and the coefficient of variation for the separation with magnetizable charcoal was 0.5%.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry, medical,Clinical Biochemistry
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献