Affiliation:
1. Endocrine and Diabetes Service, Queen Elizabeth Hospital, Woodville, Australia
Abstract
Abstract
Intraindividual variation (CVi) for glycohemoglobin (GHb) was estimated from serial measurements in patients with diabetes in either stable or variable clinical control. GHb determinations were performed by an affinity column procedure with an analytical imprecision of 4.9% (weighted average; GHb 8.2-14.7%). Within the groups of patients, both a short- (28-32 days) and long-term (approximately 85 days) sampling protocol was used. The derived CVi for each category was 4.2% (n = 16, stable, short-term), 7.1% (n = 23, stable, long-term), 5.1% (n = 13, variable, short-term), and 9.8% (n = 21, variable, long-term). The mean GHb within each category was similar (approximately 11%), and there was no statistically significant difference in GHb values between categories. The results establish that the CVi for GHb is affected by both clinical control and the sampling time interval. These findings have important implications for the estimation of significant differences between serial GHb measurements and the setting of appropriate analytical precision goals.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry, medical,Clinical Biochemistry
Cited by
47 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献