Affiliation:
1. Clinical Laboratory, Childrens Hospital, Los Angeles, CA 90027
Abstract
Abstract
This high-performance liquid-chromatographic (HPLC) method for simultaneous determination of prednisone and its metabolite, prednisolone, in plasma is a modification of the method of Frey et al. (Clin Chem 1979;25:1944-7). Heparinized plasma (1.0 mL) with 0.1 mL of internal standard solution (11-deoxy-17-hydroxycorticosterone, 2 mg/L) is extracted with 7.0 mL of dichloromethane, then washed sequentially with 0.1 mol/L HCl, 0.1 mol/L NaOH, and deionized water, 2.0 mL each. The extract is evaporated and the residue reconstituted with 75 microL of mobile phase, methanol/H2O (40/60 by vol). Thirty microliters of this is injected onto a reversed-phase C6 column, which is eluted at 1.4 mL/min. Analytical recoveries of prednisone and prednisolone were 94-98% and 102-106%, respectively. Day-to-day precision (CV) was 3.8% for prednisone, 6.1% for prednisolone. We encountered no interference from the 21 other steroids and 25 drugs tested. This method is simple, accurate, and precise.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry, medical,Clinical Biochemistry
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献