Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction

Author:

Yamada Takahiro12,Takao Seishin345,Koyano Hidenori6,Nihongi Hideaki1,Fujii Yusuke1,Hirayama Shusuke12,Miyamoto Naoki345,Matsuura Taeko345,Umegaki Kikuo345,Katoh Norio57,Yokota Isao8,Shirato Hiroki59,Shimizu Shinichi3510

Affiliation:

1. Hitachi Ltd. 1-1 7-chome, Oomika-cho, Hitachi-shi, Ibaraki 319-1292, Japan

2. Graduate School of Biomedical Science and Engineering, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

3. Department of Medical Physics, Hokkaido University Hospital, North14 West5, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

4. Division of Quantum Science and Engineering, Faculty of Engineering, Hokkaido University, North13 West8, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

5. Global Station of Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

6. Department of Medical Physics, Graduate School of Medicine, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

7. Department of Therapeutic Radiology, Faculty of Medicine, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

8. Department of Biostatistics, Graduate School of Medicine, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

9. Department of Proton Beam Therapy, Faculty of Medicine, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

10. Department of Radiation Medical Science and Engineering, Faculty of Medicine, Hokkaido University, North15 West7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan

Abstract

Abstract In spot scanning proton therapy (SSPT), the spot position relative to the target may fluctuate through tumor motion even when gating the radiation by utilizing a fiducial marker. We have established a procedure that evaluates the delivered dose distribution by utilizing log data on tumor motion and spot information. The purpose of this study is to show the reliability of the dose distributions for liver tumors treated with real-time-image gated SSPT (RGPT). In the evaluation procedure, the delivered spot information and the marker position are synchronized on the basis of log data on the timing of the spot irradiation and fluoroscopic X-ray irradiation. Then a treatment planning system reconstructs the delivered dose distribution. Dose distributions accumulated for all fractions were reconstructed for eight liver cases. The log data were acquired in all 168 fractions for all eight cases. The evaluation was performed for the values of maximum dose, minimum dose, D99, and D5–D95 for the clinical target volumes (CTVs) and mean liver dose (MLD) scaled by the prescribed dose. These dosimetric parameters were statistically compared between the planned dose distribution and the reconstructed dose distribution. The mean difference of the maximum dose was 1.3% (95% confidence interval [CI]: 0.6%—2.1%). Regarding the minimum dose, the mean difference was 0.1% (95% CI: −0.5%—0.7%). The mean differences of D99, D5–D95 and MLD were below 1%. The reliability of dose distributions for liver tumors treated with RGPT-SSPT was shown by the evaluation of the accumulated dose distributions.

Funder

AMED

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation