Abstract

Abstract Reduction in setup errors is advocated through daily imaging and adaptive therapy, where the target volume is drawn daily. Previous studies suggest that inter-physician volume variation is significant (1.5 cm standard deviation [SD]); however, there are limited data for intra-physician consistency in daily target volume delineation, which is investigated in this study. Seven patients with lung cancer were chosen based on the perceived difficulty of contouring their disease, varying from simple parenchymal lung nodules to lesions with extensive adjacent atelectasis. Four physicians delineated the gross tumor volume (GTV) for each patient on 10 separate days to see the intra- and inter-physician contouring. Isocenter coordinates (x, y and z), target volume (cm3), and largest dimensions on anterior–posterior (AP) and lateral views were recorded for each GTV. Our results show that the variability among the physicians was reflected by target volumes ranging from +109% to −86% from the mean while isocenter coordinate changes were minimal; 3.8, 1.7 and 1.9 mm for x, y and z coordinates, respectively. The orthogonal image (AP and lateral) change varied 16.3 mm and 15.0 mm respectively among days and physicians. We conclude than when performing daily imaging, random variability in contouring resulted in isocenter changes up to ±3.8 mm in our study. The shape of the target varied within ±16 mm. This study suggests that when using daily imaging to track isocenter, target volume, or treatment parameters, physicians should be aware of personal variability when considering margins added to the target volume in daily decision making especially for difficult cases.

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3