Intra-patient and inter-observer image quality analysis in liver MRI study with gadoxetic acid using two different multi-arterial phase techniques

Author:

Castagnoli Francesca12ORCID,Faletti Riccardo3ORCID,Inchingolo Riccardo4,Villanacci Alberta5,Ruggeri Valeria5,Zacà Domenico6,Koh Dow-Mu12,Grazioli Luigi5

Affiliation:

1. Department of Radiology, Royal Marsden Hospital , Sutton SM2 5PT, United Kingdom

2. Division of Radiotherapy and Imaging, The Institute of Cancer Research , Sutton SM2 5NG, United Kingdom

3. Department of Surgical Sciences, Radiology Unit, University of Turin , Turin 10124, Italy

4. Interventional Radiology Unit, “F. Miulli” General Regional Hospital , Acquaviva delle Fonti 70021, Italy

5. Department of I Radiology, ASST Spedali Civili , Brescia 25123, Italy

6. Siemens Healthcare , Milano 20218, Italy

Abstract

Abstract Purpose To evaluate intra-patient and interobserver agreement in patients who underwent liver MRI with gadoxetic acid using two different multi-arterial phase (AP) techniques. Methods A total of 154 prospectively enrolled patients underwent clinical gadoxetic acid-enhanced liver MRI twice within 12 months, using two different multi-arterial algorithms: CAIPIRINHA-VIBE and TWIST-VIBE. For every patient, breath-holding time, body mass index, sex, age were recorded. The phase without contrast media and the APs were independently evaluated by two radiologists who quantified Gibbs artefacts, noise, respiratory motion artefacts, and general image quality. Presence or absence of Gibbs artefacts and noise was compared by the McNemar’s test. Respiratory motion artefacts and image quality scores were compared using Wilcoxon signed rank test. Interobserver agreement was assessed by Cohen kappa statistics. Results Compared with TWIST-VIBE, CAIPIRINHA-VIBE images had better scores for every parameter except higher noise score. Triple APs were always acquired with TWIST-VIBE but failed in 37% using CAIPIRINHA-VIBE: 11% have only one AP, 26% have two. Breath-holding time was the only parameter that influenced the success of multi-arterial techniques. TWIST-VIBE images had worst score for Gibbs and respiratory motion artefacts but lower noise score. Conclusion CAIPIRINHA-VIBE images were always diagnostic, but with a failure of triple-AP in 37%. TWIST-VIBE was successful in obtaining three APs in all patients. Breath-holding time is the only parameter which can influence the preliminary choice between CAIPIRINHA-VIBE and TWIST-VIBE algorithm. Advances in knowledge If the patient is expected to perform good breath-holds, TWIST-VIBE is preferable; otherwise, CAIPIRINHA-VIBE is more appropriate.

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. ABDOMEN BECKEN – TWIST-VIBE versus CAIPIRINHA-VIBE bei Leber-MRT;RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren;2024-07-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3