Clinical evaluation of the efficacy of limbus artificial intelligence software to augment contouring for prostate and nodes radiotherapy

Author:

Starke Alison1,Poxon Jacqueline1,Patel Kishen2,Wells Paula2,Morris Max1,Rudd Pandora2,Tipples Karen2,MacDougall Niall13ORCID

Affiliation:

1. Radiotherapy Physics, St Bartholomew’s Hospital , London EC1A 7BE, United Kingdom

2. Clinical Oncology, St Bartholomew’s Hospital , London EC1A 7BE, United Kingdom

3. Barts Cancer Institute, Queen Mary University of London , London EC1M 6BQ, United Kingdom

Abstract

Abstract Objectives To determine if Limbus, an artificial intelligence (AI) auto-contouring software, can offer meaningful time savings for prostate radiotherapy treatment planning. Methods Three clinical oncologists recorded the time taken to contour prostate and seminal vesicles, lymph nodes, bladder, rectum, bowel, and femoral heads on CT scans for 30 prostate patients (15 prostate, 15 prostate and nodes). Limbus 1.6.0 was used to generate these contours on the 30 CT scans. The time taken by the oncologists to modify individual Limbus contours was noted and compared with manual contouring times. The geometric similarity of Limbus and expert contours was assessed using the Dice Similarity Coefficient (DSC), and the dosimetric impact of using un-edited Limbus organs at risk contours was studied. Results Limbus reduced the time to produce clinically acceptable contours by 26 minutes for prostate and nodes patients and by 13 minutes for the prostate only patients. DSC values of greater than 0.7 were calculated for all contours, demonstrating good initial agreement. A dosimetric study showed that 5 of the 20 plans optimized using unmodified AI structures required unnecessary compromise of PTV coverage, highlighting the importance of expert review. Conclusions Limbus offers significant time saving and has become an essential part of our clinical practice. Advances in knowledge This article is the first to include bowel and lymph nodes when assessing potential time savings using Limbus software. It demonstrates that Limbus can be used as an aid for prostate and node radiotherapy treatment planning.

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3