Acceleration of uterine 3D T2-weighted imaging by compressed SENSE—a multicentre study

Author:

Song Qingling12,Ma Changjun12,Tian Shifeng12,Meng Xing13,Chen Lihua12,Wang Nan12,Song Qingwei12,Lu Shan4,Liu Dengping4,Gui Haiyan5,Chen Honghao5,Lin Liangjie6,Xu Xiaofang6,Wang Jiazheng6,Liu Ailian12ORCID

Affiliation:

1. Department of Radiology, First Affiliated Hospital of Dalian Medical University , Dalian 116011, P. R. China

2. Dalian Medical Imaging Artificial Intelligence Engineering Technology Research Center , Dalian 116011, P. R. China

3. Department of Radiology, Dalian Women and Children Medical Center , Dalian 116033, P. R. China

4. Radiology Department, Chu Hsien-I Memorial Hospital and Tianjin Institute of Endocrinology, Tianjin Medical University , Tianjin 300134, P. R. China

5. Magnetic Resonance Department, The Fourth Hospital of Harbin , Harbin 150026, P. R. China

6. Clinical and Technical Support, Philips Healthcare, Beijing, 100036 , P. R. China

Abstract

Abstract Objectives To find the optimal acceleration factor (AF) of the compressed SENSE (CS) technique for uterine isotropic high-resolution 3D T2-weighted imaging (3D-ISO-T2WI). Methods A total of 91 female volunteers from the First Affiliated Hospital of Dalian Medical University, Chu Hsien-I Memorial Hospital and Tianjin Institute of Endocrinology, and The Fourth Hospital of Harbin were recruited. A total of 44 volunteers received uterus sagittal 3D-ISO-T2WI scans on 3.0T MRI device with different CS AFs (including SENSE3, CS3, CS4, CS5, CS6, and CS7), 51 received 3D-ISO-T2WI scans with different degrees of fat suppression (none, light, moderate, and severe), while 4 volunteers received both series of scans. Image quality was subjectively evaluated with a 3-point scoring system. Junction zone signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and myometrial SNR were also calculated. Intraclass correlation coefficients were used to analyse the consistency of the measurement results by 2 observers. Analysis of variance test or Friedman rank sum test was used to compare the differences in subjective scores, SNR, and CNR under different AFs/different degrees of fat suppression. Results Images by AFs of CS3, CS4, and CS5 had the highest SNR and CNR. Among them, CS5 had the shortest scan time. CS5 also had one of the highest subjective scores. There was no significant difference in SNR and CNR among images acquired with different degrees of fat suppression. Also, images with moderate fat suppression had the highest subjective scores. Conclusion The CS5 combined with moderate fat suppression is recommended for routine female pelvic 3D-ISO-T2WI scan. Advances in knowledge The CS5 has the highest image quality and has the shortest scan time, which is the best AF. Moderate fat suppression has the highest subjective scores. The CS5 and moderate fat suppression are the best combination for a female pelvic 3D-ISO-T2WI scan.