Impact of correcting the 2D PISA method on the quantification of functional tricuspid regurgitation severity

Author:

Tomaselli Michele12ORCID,Badano Luigi P12ORCID,Menè Roberto12ORCID,Gavazzoni Mara1ORCID,Heilbron Francesca12ORCID,Radu Noela3,Caravita Sergio24ORCID,Baratto Claudia1ORCID,Oliverio Giorgio1,Florescu Diana R.25ORCID,Parati Gianfranco2ORCID,Muraru Denisa12ORCID

Affiliation:

1. Department of Medicine and Surgery, University of Milano-Bicocca , Milan , Italy

2. Department of Cardiology, Istituto Auxologico Italiano, IRCCS , P.le Brescia 20, 20149 Milan , Italy

3. Carol Davila University of Medicine and Pharmacy , Bucharest , Romania

4. Department of Management, Information and Production Engineering, University of Bergamo , Dalmine , Italy

5. University of Medicine and Pharmacy of Craiova , Craiova , Romania

Abstract

Abstract Aims In functional tricuspid regurgitation (FTR) patients, tricuspid leaflet tethering and relatively low jet velocity could result in proximal flow geometry distortions that lead to underestimation of TR. Application of correction factors on two-dimensional (2D) proximal isovelocity surface area (PISA) equation may increase its reliability. This study sought to evaluate the impact of the corrected 2D PISA method in quantifying FTR severity. Methods and results In 102 patients with FTR, we compared both conventional and corrected 2D PISA measurements of effective regurgitant orifice area [EROA vs. corrected (EROAc)] and regurgitant volume (RegVol vs. RegVolc) with those obtained by volumetric method (VM) using three-dimensional echocardiography (3DE), as reference. Both EROAc and RegVolc were larger than EROA (0.29 ± 0.26 vs. 0.22 ± 0.21 cm2; P < 0.001) and RegVol (24.5 ± 20 vs. 18.5 ± 14.25 mL; P < 0.001), respectively. Compared with VM, both EROAc and RegVolc resulted more accurate than EROA [bias = −0.04 cm2, limits of agreement (LOA) ± 0.02 cm2 vs. bias = −0.15 cm2, LOA ± 0.31 cm2] and RegVol (bias = −3.29 mL, LOA ± 2.19 mL vs. bias = −10.9 mL, LOA ± 13.5 mL). Using EROAc and RegVolc, 37% of patients were reclassified in higher grades of FTR severity. Corrected 2D PISA method led to a higher concordance of TR severity grade with the VM method (ĸ = 0.84 vs. ĸ = 0.33 for uncorrected PISA, P < 0.001). Conclusion Compared with VM by 3DE, the conventional PISA underestimated FTR severity in about 50% of patients. Correction for TV leaflets tethering angle and lower velocity of FTR jet improved 2D PISA accuracy and reclassified more than one-third of the patients.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3