Warranty period of coronary computed tomography angiography and [15O]H2O positron emission tomography in symptomatic patients

Author:

Jukema Ruurt1ORCID,Maaniitty Teemu23ORCID,van Diemen Pepijn1,Berkhof Hans4,Raijmakers Pieter G5,Sprengers Ralf5,Planken R Nils5,Knaapen Paul1ORCID,Saraste Antti26,Danad Ibrahim17,Knuuti Juhani23ORCID

Affiliation:

1. Department of Cardiology, Nuclear Medicine & PET Research, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam , De Boelelaan 1117, 1081 HV Amsterdam , The Netherlands

2. Turku PET Centre, Turku University Hospital and University of Turku , Turku 20520 , Finland

3. Clinical Physiology, Nuclear Medicine and PET, Turku University Hospital and University of Turku , Turku 20520 , Finland

4. Department of Epidemiology & Data Science, Nuclear Medicine & PET Research, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam , De Boelelaan 1117, 1081 HV Amsterdam , The Netherlands

5. Department of Radiology, Nuclear Medicine & PET Research, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam , De Boelelaan 1117, 1081 HV Amsterdam , The Netherlands

6. Heart Center, Turku University Hospital , Turku 20520 , Finland

7. Department of Cardiology, University Medical Center Utrecht , Heidelberglaan 100, 3584 CX Utrecht , The Netherlands

Abstract

AbstractAimsData on the warranty period of coronary computed tomography angiography (CTA) and combined coronary CTA/positron emission tomography (PET) are scarce. The present study aimed to determine the event-free (warranty) period after coronary CTA and the potential additional value of PET.Method and resultsPatients with suspected but not previously diagnosed coronary artery disease (CAD) who underwent coronary CTA and/or [15O]H2O PET were categorized based upon coronary CTA as no CAD, non-obstructive CAD, or obstructive CAD. A hyperaemic myocardial blood flow (MBF) ≤ 2.3 mL/min/g was considered abnormal. The warranty period was defined as the time for which the cumulative event rate of death and non-fatal myocardial infarction (MI) was below 5%. Of 2575 included patients (mean age 61.4 ± 9.9 years, 41% male), 1319 (51.2%) underwent coronary CTA only and 1237 (48.0%) underwent combined coronary CTA/PET. During a median follow-up of 7.0 years 163 deaths and 68 MIs occurred. The warranty period for patients with no CAD on coronary CTA was ≥10 years, whereas patients with non-obstructive CAD had a 5-year warranty period. Patients with obstructive CAD and normal hyperaemic MBF had a 2-year longer warranty period compared to patients with obstructive CAD and abnormal MBF (3 years vs. 1 year).ConclusionAs standalone imaging, the warranty period for normal coronary CTA is ≥10 years, whereas patients with non-obstructive CAD have a warranty period of 5 years. Normal PET yielded a 2-year longer warranty period in patients with obstructive CAD.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3