Correlation between non-invasive myocardial work indices and main parameters of systolic and diastolic function: results from the EACVI NORRE study

Author:

Manganaro Roberta1,Marchetta Stella1,Dulgheru Raluca1,Sugimoto Tadafumi12,Tsugu Toshimitsu13,Ilardi Federica14,Cicenia Marianna1,Ancion Arnaud1,Postolache Adriana1,Martinez Christophe1,Kacharava George5,Athanassopoulos George D6,Barone Daniele7,Baroni Monica8,Cardim Nuno9,Hagendorff Andreas10,Hristova Krasimira11,Lopez Teresa12,de la Morena Gonzalo13,Popescu Bogdan A14,Penicka Martin15,Ozyigit Tolga16,Rodrigo Carbonero Jose David17,van de Veire Nico18,Von Bardeleben Ralph Stephan19,Vinereanu Dragos20,Zamorano Jose Luis21,Rosca Monica14,Calin Andreea14,Moonen Marie1,Magne Julien2223,Cosyns Bernard24,Galli Elena25,Donal Erwan25,Carerj Scipione26,Zito Concetta26,Santoro Ciro4,Galderisi Maurizio4,Badano Luigi P27,Lang Roberto M28,Lancellotti Patrizio129

Affiliation:

1. Department of Cardiology, University of Liège Hospital, GIGA Cardiovascular Sciences, Heart Valve Clinic, CHU du Sart Tilman, Domaine Universitaire du Sart Tilman, Batiment B35, 4000 Liège, Belgium

2. Department of Clinical Laboratory, Mie University Hospital, Mie, 2-174 Edobashi, 514-8507 Tsu, Japan

3. Department of Cardiology, School of Medicine, Keio University, 160-8582 Tokyo, Japan

4. Department of Advanced Biomedical Sciences, Federico II University Hospital, Via S.Pansini, 5, 80131 Napoli, Italy

5. Department of Cardiology, Tbilisi Institute of Medicine (TIM), 16 Tsintsadze, 0160 Tbilisi, Georgia

6. Noninvasive Diagnostics Department, Onassis Cardiac Surgery Center, Leof. Andrea Siggrou 356, 176 74 Kallithea, Athens, Greece

7. Cardiology Department, Laboratory of Cardiovascular Ecography, S. Andrea Hospital, La Spezia, Italy

8. Laboratorio Di Ecocardiografia Adulti, Fondazione Toscana “G.Monasterio” - Ospedale Del Cuore, Via Giuseppe Moruzzi, 1, 56124 Pisa, Massa, Italy

9. Echocardiography Laboratory, Hospital da Luz, Av. Lusíada 100, 1500-650 Lisboa, Portugal

10. Department of Cardiology, University of Leipzig, Liebigstraße 20, 04103 Leipzig, Germany

11. Department of Noninvasive Functional Diagnostic and Imaging, University National Heart Hospital, ul. ‘Konyovitsa’ 65, 1309 g.k. Ilinden, Sofia, Bulgaria

12. Cardiology Department, La Paz Hospital, Paseo de la Castellana, 261, 28046 Madrid, Spain

13. Unidad de Imagen Cardiaca, Servicio de Cardiologia, Hospital Clinico Universitario Virgen de la Arrixaca, IMIB-Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 El Palmar, Murcia, Spain

14. Department of Cardiology, University of Medicine and Pharmacy ‘Carol Davila’, Euroecolab, Institute of Cardiovascular Diseases ‘Prof. Dr. C. C. Iliescu’, Sos. Fundeni 258, sector 2, 022328 Bucharest, Romania

15. Cardiovascular Center Aalst, OLV-Clinic, Moorselbaan 164, 9300 Aalst, Belgium

16. VKV Amerikan Hastanesi, Kardiyoloji Bölümü, Tes v¸ikiye, Güzelbahçe Sok, No: 20, 34365 Nişantaşı Istanbul Turkey

17. Laboratorio de Ecocardiografia Hospital de Cruces, Plaza de Cruces, S/N, 48903 Baracaldo, Vizcaya, Spain

18. Echocardiography Unit, AZ Maria Middelares Gent, Buitenring-Sint-Denijs 30, 9000 Gent, Belgium

19. Medical Department Cardiology, Universitätsmedizin of the Johannes Gutenberg-University Mainz, Langenbeckstraße 1, 55131 Mainz, Germany

20. Cardiovascular Research Unit, University and Emergency Hospital, University of Medicine and Pharmacy Carol Davila, Sector 1, Strada Dionisie Lupu 37, 030167 Bucureşti, Romania

21. University Alcala, Hospital Ramón y Cajal, Ctra. De Colmenar Viejo, km. 9, 100, 28034 Madrid, Spain

22. CHU Limoges, Hôpital Dupuytren, Service Cardiologie, Limoges F-87042, France

23. INSERM 1094, Faculté de médecine de Limoges, 2, rue Marcland, 87000 Limoges, France

24. CHVZ (Centrum voor Hart en Vaatziekten), Universitair ziekenhuis Brussel and ICMI (In Vivo Cellular and Molecular Imaging) Laboratory, Avenue du Laerbeek 101, 1090 Jette, Brussels, Belgium

25. CIC-IT U 1414, CHU Rennes, Université Rennes 1, Service de Cardiologie, CHU Rennes, 2 Rue Henri le Guilloux, 35000 Rennes, France

26. Department of Clinical and Experimental Medicine, Section of Cardiology, University of Messina, 1, Via Consolare Valeria - 98125 Messina (IT), Italy

27. Department of Medicine and Surgery, University Milano-Bicocca, and Istituto Auxologico Italiano, IRCCS, Cardiology Unit and Dept of Cardiovascular, Neural and Metabolic Sciences, San Luca Hospital, P.le Brescia 20, 20149 Milano, Italy

28. Department of Medicine, University of Chicago Medical Center, 5841 S Maryland Ave, Chicago, 60637 IL, USA

29. Gruppo Villa Maria Care and Research, Anthea Hospital, Via Camillo Rosalba, 35, 70124 Bari, Italy

Abstract

Abstract Aims The present study sought to evaluate the correlation between indices of non-invasive myocardial work (MW) and left ventricle (LV) size, traditional and advanced parameters of LV systolic and diastolic function by 2D echocardiography (2DE). Methods and results A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from LV pressure-strain loops using custom software. Peak LV pressure was estimated non-invasively from brachial artery cuff pressure. LV size, parameters of systolic and diastolic function and ventricular-arterial coupling were measured by echocardiography. As advanced indices of myocardial performance, global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) were obtained. On multivariable analysis, GWI was significantly correlated with GLS (standardized beta-coefficient = −0.23, P < 0.001), ejection fraction (EF) (standardized beta-coefficient = 0.15, P = 0.02), systolic blood pressure (SBP) (standardized beta-coefficient = 0.56, P < 0.001) and GRS (standardized beta-coefficient = 0.19, P = 0.004), while GCW was correlated with GLS (standardized beta-coefficient = −0.55, P < 0.001), SBP (standardized beta-coefficient = 0.71, P < 0.001), GRS (standardized beta-coefficient = 0.11, P = 0.02), and GCS (standardized beta-coefficient = −0.10, P = 0.01). GWE was directly correlated with EF and inversely correlated with Tei index (standardized beta-coefficient = 0.18, P = 0.009 and standardized beta-coefficient = −0.20, P = 0.004, respectively), the opposite occurred for GWW (standardized beta-coefficient =−−0.14, P = 0.03 and standardized beta-coefficient = 0.17, P = 0.01, respectively). Conclusion The non-invasive MW indices show a good correlation with traditional 2DE parameters of myocardial systolic function and myocardial strain.

Funder

GE Healthcare and Philips Healthcare

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3