Affiliation:
1. Division of Cardiology, Department of Cardiovascular Diseases, Cliniques Universitaires St. LucPôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain (UCLouvain), Av Hippocrate 10/2806, B-1200 Woluwe St. Lambert, Brussels, Belgium
2. Afdeling Hart en Vaatziekten, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Avenue du Laerbeek 101, B-1090 Brussels, Belgium
Abstract
Abstract
Aims
Reproducible evaluation of left (LV) and right ventricular (RV) function is crucial for clinical decision-making and risk stratification. We evaluated whether speckle-tracking echocardiography (STE) and cardiac magnetic resonance feature-tracking (cMR-FT) global longitudinal (GLS) and circumferential strains allow better test–retest reproducibility of LV and RV systolic function than conventional cMR and echocardiographic parameters.
Methods and results
Thirty healthy volunteers and 20 chronic heart failure patients underwent cMR and STE twice on separate days to evaluate test–retest coefficient of variation (CV), intraclass correlation coefficient (ICC) and estimated sample sizes for significant changes in LV and RV function. Among LV parameters, cMR-left ventricular ejection fraction (LVEF) had the highest reproducibility (CV = 6.7%, ICC = 0.98), significantly better than cMR-FT-GLS (CV = 15.1%, ICC = 0.84), global circumferential strains (CV = 11.5%, ICC = 0.94) and echocardiographic LVEF (CV = 11.3%, ICC = 0.93). STE-LV-GLS (CV = 8.9%, ICC = 0.94) had significantly better reproducibility than cMR-FT-LV-GLS. Among RV parameters, STE-RV-GLS (CV = 7.3%, ICC = 0.93) had significantly better CV than cMR-right ventricular ejection fraction (RVEF) (CV = 13%, ICC = 0.82). cMR-FT-RV-GLS (CV = 43%, ICC = 0.39) performed poorly with significantly lower reproducibility than all other RV parameters. Owing to their superior interstudy reproducibility, cMR-LVEF (n = 12), cMR-RVEF (n = 41), STE-LV-GLS and STE-RV-GLS (both n = 14) were the parameters allowing the lowest calculated sample sizes to detect 10% change in LV or RV systolic function.
Conclusion
STE-LV-GLS and STE-RV-GLS showed higher test–retest reliability than other echocardiographic measurements of LV and RV function. They also allowed smaller calculated sample sizes, supporting the use of STE-LV and RV-GLS for longitudinal follow-up of LV and RV function.
Funder
Fondation Nationale de la Recherche Scientifique of the Belgian Government
Publisher
Oxford University Press (OUP)
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine
Cited by
27 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献