The ratio of measured and reference effective orifice areas for discriminating prosthetic aortic valve obstruction

Author:

Kim Kyu1ORCID,Kim Dae-Young1,Seo Jiwon1,Cho Iksung1ORCID,Shim Chi Young1,Hong Geu-Ru1ORCID,Ha Jong-Won1ORCID

Affiliation:

1. Division of Cardiology, Severance Hospital Yonsei University College of Medicine , 50 Yonsei-ro, Seodaemun-gu, Seoul 120-752 , Korea

Abstract

Abstract Aims We aimed to evaluate the efficacy of the measured effective orifice area (EOA)/reference EOA ratio in discriminating mechanical prosthetic aortic valve (PAV) obstruction. Methods and results This is a retrospective study of 193 mechanical PAV patients with an elevated mean transprosthetic pressure gradient (PG) over 20 mmHg or peak velocity over 3 m/s. Of those, 143 patients were objectively proven PAV obstruction with cardiac computed tomography or surgical inspection. The EOA was measured using the continuity equation, and the reference EOA values were obtained from previous guidelines. The measured/reference EOA ratio was significantly lower in the obstruction group (0.63 ± 0.18 vs. 0.86 ± 0.17; P < 0.001). The EOA ratio added incremental value for discriminating obstruction from the conventional parameters recommended in the guidelines. Receiver operating characteristic curve analysis revealed that the measured/reference EOA ratio discriminated PAV obstruction from those without obstruction [area under the curve (AUC), 0.840; 95% confidence interval, 0.783–0.898; P < 0.001]. A cutoff of 0.71 had 73.4% sensitivity and 82.0% specificity. The novel diagnostic algorithm adding the EOA ratio had similar accuracy to previous guideline algorithms, including reference EOA, and conventional Doppler parameters (AUC, 0.763 vs. 0.731; P = 0.309). In patients with a large PAV (≥23 mm), the novel algorithm had higher accuracy than the previous algorithm (AUC, 0.788 vs. 0.642; P = 0.019). Conclusion The ratio of measured/reference EOA adds incremental value over conventional Doppler parameters and might be helpful for distinguishing PAV obstruction.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3