Atrial fibrillation is associated with large beat-to-beat variability in mitral and tricuspid annulus dimensions

Author:

Naser Jwan A1ORCID,Kucuk Hilal Olgun1,Ciobanu Andrea O23,Jouni Hayan1,Oguz Didem1,Thaden Jeremy J1,Pislaru Cristina1,Pellikka Patricia A1,Foley Thomas A4,Eleid Mackram F1,Muraru Denisa5,Nkomo Vuyisile T1,Pislaru Sorin V1

Affiliation:

1. Department of Cardiovascular Medicine, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA

2. University of Medicine and Pharmacy Carol Davila, Bucharest, Romania

3. University and Emergency Hospital Bucharest, Bucharest, Romania

4. Department of Radiology, Mayo Clinic College of Medicine, Rochester, MN 55905, USA

5. IRCCS, Instituto Auxologico Italiano, S. Luca Hospital, University of Milano-Bicocca, Milan, Italy

Abstract

Abstract Aims Beat-to-beat variability in cycle length is well-known in atrial fibrillation (Afib); whether this also translates to variability in annulus size remains unknown. Defining annulus maximal size in Afib is critical for accurate selection of percutaneous devices given the frequent association with mitral and tricuspid valve diseases. Methods and results Images were obtained from 170 patients undergoing 3D echocardiography [100 (50 sinus rhythm (SR) and 50 Afib) for mitral annulus (MA) and 70 (35 SR and 35 Afib) for tricuspid annulus (TA)]. Images were analysed for differences in annular dynamics with a commercially available software. Number of cardiac cycles analysed was 567 in mitral valve and 346 in tricuspid valve. Median absolute difference in maximal MA area over four to six cycles was 1.8 cm2 (range 0.5–5.2 cm2) in Afib vs. 0.8 cm2 (range 0.1–2.9 cm2) in SR, P < 0.001. Maximal MA area was observed within 30–70% of the R-R interval in 81% of cardiac cycles in SR and in 73% of cycles in Afib. Median absolute difference in maximal TA area over four to six cycles was 1.4 cm2 (range 0.5–3.6 cm2) in Afib vs. 0.7 cm2 (range 0.3–1.7 cm2) in SR, P < 0.001. Maximal TA area was observed within 60–100% of the R-R interval in 81% of cardiac cycles in SR, but only in 49% of cycles in Afib. Conclusion MA and TA reach maximal size within a broad time interval centred around end-systole and end-diastole, respectively, with significant beat-to-beat variability. Afib leads to a larger beat-to-beat variability in both timing of occurrence and values of annulus size than in SR.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献