Gastroscopy Should Come Before Colonoscopy Using CO2 Insufflation in Same Day Bidirectional Endoscopies: A Randomized Controlled Trial

Author:

Jowhari Fahd1,Hookey Lawrence1

Affiliation:

1. Gastrointestinal Diseases Research Unit, Department of Medicine, Queen’s University, Kingston, Ontario, Canada

Abstract

Abstract Background and Aims Same day bidirectional endoscopies (esophagogastroduodenoscopies [EGD]s and colonoscopies) are routinely performed. However, the best sequence of procedures is unknown, as is whether the use of carbon dioxide (CO2) affects the preferred sequence of procedures. This study aims to determine the preferred sequence of procedures and choice of insufflation gas (air or CO2) in patients undergoing same day bidirectional endoscopies. Methods Two hundred adults with a clinical indication for same day bidirectional endoscopies were randomized equally into four groups: A1 (EGD first, CO2 as insufflator); A2 (EGD first, air as insufflator); B1 (colonoscopy first, CO2 as insufflator); and B2 (colonoscopy first, air as insufflator). All procedures were performed with conscious sedation (Midazolam/Fentanyl). The primary outcome was patients’ overall comfort/satisfaction with the procedures and sedation received, as assessed by questionnaires and validated scoring scales (Nurse-Assessed Patient Comfort Score [NAPCOMS], La Crosse [WI]) collected during the procedures, before discharge, and on day 7 postprocedure. Results Two hundred patients were randomized, with data available for 186. Mean Midazolam dose between groups was significantly less in the EGD first groups (P=0.01). During the procedures, no differences were found in patients’ comfort as per the nurse reported NAPCOMS scores (P=0.19) or the Lacrosse (WI) endoscopy scores (P=0.05). On postprocedure days 0 and 7, no differences were found in the patients’ reported Lacrosse (WI) scores, nausea, sore throat, dizziness, satisfaction with sedation or overall level of procedural satisfaction (P>0.05 for each). However, bloating and discomfort were significantly lower in the CO2 arms (P<0.001). Conclusions This randomized controlled trial using validated patient comfort scoring assessments for same day bidirectional endoscopies demonstrated that the sequence of procedures affects the sedation used but does not affect overall patient comfort or satisfaction. Lesser sedation is needed in the EGD first group, and less postprocedural abdominal pain/discomfort and bloating is seen with CO2 insufflation.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3