Abstract
Objective
To evaluate the effect of prior comparison MRI on interpretive performance of screening breast MRI.
Methods
After institutional review board approval, all screening breast MRI examinations performed from January 2011 through December 2014 were retrospectively reviewed. Screening performance metrics were estimated and compared for exams with and without a prior comparison MRI, using logistic regression models to adjust for age and screening indication (BRCA mutation or thoracic radiation versus breast cancer history versus high-risk lesion history versus breast cancer family history).
Results
Most exams, 4509 (87%), had a prior comparison MRI (incidence round), while 661 (13%) did not (prevalence round). Abnormal interpretation rate (6% vs 20%, P < 0.01), biopsy rate (3% vs 9%, P < 0.01), and false-positive biopsy recommendation rate per 1000 exams (21 vs 71, P < 0.01) were significantly lower in the incidence rounds compared to the prevalence rounds, while specificity was significantly higher (95% vs 81%, P < 0.01). There was no difference in cancer detection rate (CDR) per 1000 exams (12 vs 20, P = 0.1), positive predictive value of biopsies performed (PPV3) (35% vs 23%, P = 0.1), or sensitivity (86% vs 76%, P = 0.4).
Conclusion
Presence of a prior comparison significantly improves incidence round screening breast MRI examination performance compared with prevalence round screening. Consideration should be given to updating the BI-RADS breast MRI screening benchmarks and auditing prevalence and incidence round examinations separately.
Publisher
Oxford University Press (OUP)
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Reference21 articles.
1. Differences between first and subsequent rounds of the MRISC breast cancer screening program for women with a familial or genetic predisposition;Kriege,2006
2. Mammography, breast ultrasound, and magnetic resonance imaging for surveillance of women at high familial risk for breast cancer;Kuhl;J Clin Oncol,2005
3. Surveillance of BRCA1 and BRCA2 mutation carriers with magnetic resonance imaging, ultrasound, mammography, and clinical breast examination;Warner;JAMA,2004
4. Multicenter comparative multimodality surveillance of women at genetic-familial high risk for breast cancer (HIBCRIT study): interim results;Sardanelli;Radiology,2007
5. Screening with magnetic resonance imaging and mammography of a UK population at high familial risk of breast cancer: a prospective multicentre cohort study (MARIBS);Leach;Lancet,2005
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献