Impact of Colorized Display of Mammograms on Lesion Detection

Author:

Knippa Emily E1ORCID,Berg Erica2,Richard Samuel3,Lin Yuan4,Roy Choudhury Kingshuk5,Samei Ehsan6,Baker Jay A7

Affiliation:

1. University of Texas Southwestern Medical Center, Department of Radiology, Dallas, TX

2. Wisconsin Radiology Specialists, Milwaukee, WI

3. Carestream Health, Rochester, NY

4. OPPO US Research Center, AI Department, Palo Alto, CA

5. Duke University, Department of Biostatistics and Bioinformatics, Durham, NC

6. Duke University, Departments of Radiology, Physics, and Biomedical Engineering, and Electrical and Computer Engineering, Durham, NC

7. Duke University Hospital, Department of Radiology, Durham, NC

Abstract

Abstract Objective To assess the effect of the colorized display of digital mammograms on observer detection of subtle breast lesions. Methods Three separate observer studies compared detection performance using grayscale versus color display of 1) low-contrast mass-like objects in a standardized mammography phantom; 2) simulated microcalcifications in a background of normal breast parenchyma; and 3) standard-of-care clinical digital mammograms with subtle calcifications and masses. Colorization of the images was done by displaying each image pixel in blue, green, and red hues, or gray, maintaining DICOM–calibrated luminance scale and consistent luminance range. For the simulated calcifications and clinical mammogram studies, comparison of detection rates was computed using McNemar’s test for paired differences. Results For the phantom study, mass-like object detection was significantly better using a green colormap than grayscale (73.3% vs 70.8%, P = .009), with no significant improvement using blue or red colormaps (72.6% and 72.5%, respectively). For simulated microcalcifications, no significant difference was noted in detection using the green colormap, as compared with grayscale. For clinical digital screening mammograms, no significant difference was noted between gray and green colormaps for detection of microcalcifications. Green color display, however, resulted in decreased sensitivity for detection of subtle masses (63% vs 69%, P = .03). Conclusion Although modest improvement was demonstrated for a detection task using colorized display of a standard mammography phantom, no significant improvement was demonstrated using a color display for a simulated clinical detection task, and actual clinical performance was worse for colorized display of mammograms in comparison to standard grayscale display.

Publisher

Oxford University Press (OUP)

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3