Determining Intraosseous Needle Placement Using Point-of-Care Ultrasound in a Swine (Sus scrofa) Model

Author:

Kyle Adrianna I1ORCID,Auten Jonathan D1,Zarow Gregory J2,Natarajan Ramesh1,Bianchi William D1,Speicher Matthew V1,Palma James1,Gaspary Micah J1

Affiliation:

1. Clinical Investigation Department, Combat Trauma Research Group, Naval Medical Center Portsmouth, Portsmouth, VA 23708, USA

2. The Emergency Statistician, Idyllwild, USA

Abstract

ABSTRACT Objective Intraosseous (IO) access is critical in resuscitation, providing rapid access when peripheral vascular attempts fail. Unfortunately, misplacement commonly occurs, leading to possible fluid extravasation and tissue necrosis. Current research exploring the utility of bedside ultrasound in confirming IO line placement is limited by small sample sizes of skeletally immature subjects or geriatric cadaveric models. The objective of this study was to investigate the potential value of ultrasound confirming IO needle placement in a live tissue model with bone densities approximated to the young adult medical or trauma patient. Materials and Methods In this randomized, blinded prospective study, IO devices were placed into the bilateral humeri of 36 sedated adult swine (N = 72) with bone densities approximating that of a 20-39-year-old adult. Of the 72 lines, 53 were randomized to the IO space (“correct”) and 19 into the subcutaneous tissue (“incorrect”). Four emergency physicians with variable ultrasound experience and blinded to needle location independently assessed correct or incorrect needle placements based on the presence of an intramedullary “flare” on color power Doppler (CPD) during a saline flush. Participants adjusted the ultrasound beam trajectory and recorded assessments up to three times, totaling 204 separate observations. Results Overall, sensitivity for placement confirmation was 72% (95% CI: 64%-79%). Specificity was 79% (95% CI: 66%-89%). First assessment and final assessment results were similar. More experienced sonographers demonstrated greater success in identifying inaccurate placements with a specificity of 86% (95% CI: 63%-96%). Conclusion Within the context of this study, point-of-care ultrasound with CPD did not reliably confirm IO line placement. However, more accurate assessments of functional and malpositioned catheters were noted in sonographers with greater than 4 years of experience. Future study into experienced sonographers’ use of CPD to confirm IO catheter placement is needed.

Funder

Congressionally Directed Medical Research Programs

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3