Effectiveness of Selected Air Cleaning Devices During Dental Procedures

Author:

Maurais T1,Kriese J1,Fournier M2,Langevin L2,MacLeod B2,Blier S1,Tessier-Guay J P1,Girardin A1,Maheux L1

Affiliation:

1. Directorate of Force Health Protection, Canadian Forces Health Services Group Headquarters, Ottawa, ON K1A 0K2, Canada

2. Directorate of Dental Services, Canadian Forces Health Services Group Headquarters, Ottawa, ON K1A 0K2, Canada

Abstract

ABSTRACT Introduction The recent COVID-19 pandemic has underscored the necessity of protecting health care providers (HCPs) against the transmission of infectious agents during dental procedures. To this end, the effectiveness of several air cleaning devices (ACDs) in reducing HCPs exposure to aerosols generated during dental procedures was estimated, separately or in combination with each other. These ACDs were a chairside unit capturing aerosols at the source of generation, and four ambient ACDs: a portable ambient ACD; a negative pressure module; a custom made, fan-operated and wall-mounted air filter (WMAF); and a smaller and passive version of the latter. The last three ACDs were intended for mobile dental clinics (MDCs) only. Materials and Methods This assessment was performed in two different environments: in a dental clinic operatory and in a MDC. Two dental personnel, acting in the roles of dentist and dental assistant, performed on simulated patient aerosol-generating and non-aerosol-generating procedures. For each 5-minute scenario, the cumulative exposure to airborne particulate matter 10 µm in size or smaller (PM10) was determined by calculating the sum of all 1 second readings obtained with personal and ambient air monitors. The effectiveness of the ACDs in capturing PM10 was estimated based on the capability of the ACDs to keep PM10 level at or below the initial background level. Results In all conditions assessed in the dental clinic operatory, when both the chairside and portable ambient ACDs were functioning, an estimated effectiveness of 100% in capturing PM10 was achieved. In the MDC, in all conditions where the chairside ACD was used without the negative pressure module, an estimated effectiveness of 100% was also achieved. The simultaneous operation of the negative pressure module in the MDC, which led to a room negative pressure of −0.25 inch wc, reduced the chairside ACD’s effectiveness in capturing aerosols. Conversely, the use of the WMAF in the MDC in combination with the chairside ACD further reduced exposure to PM10 below the initial background level. Nonetheless, in all conditions assessed in both settings (dental clinic operatory and MDC), larger visible aerosols were produced, often landing on the surrounding environment. A fair portion of these aerosols landed on the inside of the chairside ACD flange. Conclusions This assessment suggests that the use of the tested chairside ACD, by capturing aerosols at the source of generation, had the greatest impact on reducing exposure of dental personnel to PM10 produced during dental procedures. This study also indicates that such exposure is further reduced with the addition of an ambient ACD. However, creating a negative pressure room as high as −0.25 inch wc can lead to air turbulence reducing the effectiveness of ACDs in capturing aerosols at the source. Furthermore, the presence of uncaptured droplets and spatter on the surrounding environment supports the need to complement the use of engineering controls with proper administrative controls and personal protective equipment, as recommended by governmental agencies and the scientific community for preventing the transmission of infection in health care settings.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3