Comparison of Biomechanical Outcome Measures From Characteristically Different Blast Simulators and the Influence of Exposure Location

Author:

Sajja Venkatasivasai1,Shoge Richard2,McNeil Elizabeth1,Van Albert Stephen1,Wilder Donna1,Long Joseph1

Affiliation:

1. Walter Reed Army Institute of Research , Silver Spring, MD 20910, USA

2. Defense Health Agency , Rockville, MD 20852, USA

Abstract

ABSTRACT Introduction Simulation of blast exposure in the laboratory has been inconsistent across laboratories. This is primarily because of adoption of the shock wave–generation techniques that are used in aerodynamic tests as opposed to application of blast exposures that are relevant to combat and training environments of a Warfighter. Because of the differences in blast signatures, characteristically different pathological consequences are observed among the preclinical studies. This is also further confounded by the varied exposure positioning of the animal subject (e.g., inside the blast simulator vs. at the mouth of the simulator). In this study, we compare biomechanical responses to blast exposures created in an advanced blast simulator (ABS) that generates “free-field”-like blast exposure with those produced by a traditionally applied cylindrical blast simulator (CBS) that generates a characteristically different blast signature. In addition, we have tested soft-armor vest protective responses with the ABS and CBS to compare the biomechanical responses to this form of personal protective equipment in each setting in a rodent model. Materials and Methods Anesthetized male Sprague–Dawley rats (n = 6) were surgically probed with an intrathoracic pressure (ITP) transducer and an intracranial pressure (ICP) transducer directed into the lateral cerebral ventricle (Millar, Inc.). An ABS for short-duration blast or a CBS for long-duration blast was used to expose animals to an incident blast overpressure of 14.14 psi (impulse: 30.27 psi*msec) or 16.3 psi (impulse: 71.9 psi*msec) using a custom-made holder (n = 3-4/group). An external pitot probe located near the animal was used to measure the total pressure (tip) and static gauge (side-on) pressure. Data were recorded using a TMX-18 data acquisition system (AstroNova Inc.). MATLAB was used to analyze the recordings to identify the peak amplitudes and rise times of the pressure traces. Peak ICP, peak ITP, and their impulses were normalized by expressing them relative to the associated peak static pressure. Results Normalized impulse (ABS: 1.02 ± 0.03 [vest] vs. 1.02 ± 0.01 [no-vest]; CBS: 1.21 ± 0.07 [vest] vs. 1.01 ± 0.01 [no-vest]) and peak pressure for ICP (ABS: 1.03 ± 0.03 [vest] vs. 0.99 ± 0.04 [no-vest]; CBS: 1.06 ± 0.08 [vest] vs. 1.13 ± 0.06 [no-vest]) remained unaltered when comparisons are made between vest and no-vest groups, and the normalized peak ITP (ABS: 1.50 ± 0.02 [vest] vs. 1.24 ± 0.16 [no-vest]; CBS: 1.71 ± 0.20 [vest] vs. 1.37 ± 0.06 [no-vest]) showed a trend of an increase in the vest group compared to the no-vest group. However, impulses in short-duration ABS (0.94 ± 0.06 [vest] vs. 0.92 ± 0.13 [no-vest]) blast remained unaltered, whereas a significant increase of ITP impulse (1.21 ± 0.07 [vest] vs. 1.17 ± 0.01 [no-vest]) in CBS was observed. Conclusions The differences in the biomechanical response between ABS and CBS could be potentially attributed to the higher dynamic pressures that are imparted from long-duration CBS blasts, which could lead to chest compression and rapid acceleration/deceleration. In addition, ICP and ITP responses occur independently of each other, with no evidence of thoracic surge.

Funder

Military Operational Medicine Research Program

Congressionally Directed Medical Research Programs

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3