Reliability and Safety Testing of a Ventilator Remote Control System Against Communication Failures and Network Disruptions

Author:

Zhang Yi1,Aroulmozhi Bragadeesh1,Arney David1,Al Zowelei Mosa1,Jaffe Michael B2,Goldman Julian M1

Affiliation:

1. Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital , Cambridge, MA 02139, USA

2. Cardiorespiratory Consulting LLC , Cheshire, CT 06410, USA

Abstract

ABSTRACT Introduction The need for remote ventilator control has been highlighted by the COVID-19 Public Health Emergency. Remote ventilator control from outside a patient’s room can improve response time to patient needs, protect health care workers, and reduce personal protective equipment (PPE) consumption. Extending remote control to distant locations can expand the capabilities of frontline health care workers by delivering specialized clinical expertise to the point of care, which is much needed in diverse health care settings, such as tele-critical care and military medicine. However, the safety and effectiveness of remote ventilator control can be affected by many risk factors, including communication failures and network disruptions. Consensus safety requirements and test methods are needed to assess the resilience and safety of remote ventilator control under communication failures and network disruptions. Materials and Methods We designed two test methods to assess the robustness, usability, and safety of a remote ventilator control prototype system jointly developed by Nihon Kohden OrangeMed, Inc. and DocBox, Inc. (“the NK-DocBox system”) to control the operation of an NKV-550 critical care ventilator under communication failures and network disruptions. First, the robustness of the NKV-550 ventilator was tested using a remote-control application developed on OpenICE - an open-source medical device interoperability platform - to transmit customized high-frequency and erroneous remote-control commands that could be caused by communication failures in a real-world environment. The second method utilized a network emulator to create different types and severity of network quality of service (QoS) degradation, including bandwidth throttling, network delay and jitter, packet drop and reordering, and bit errors, in the NKV-DocBox system to quantitatively assess the impact on system usability and safety. Results The NKV-550 ventilator operated as expected when remote-control commands arrived as fast as once per second. It ignored erroneous commands attempting to adjust invalid ventilation parameters. When facing commands that set the ventilation mode and parameters to invalid values, it reset the ventilation mode or parameters to default values, the safety implication of which may merit further evaluation. When any network QoS attribute (except for packet reordering) started to degrade, the NK-DocBox System experienced interference to its remote-control function, such as delays in the transmission of ventilator data and remote-control commands within the system. When the network QoS was worse than 500 ms network delay, 100 ms network jitter, 1% data drop rate, 12 Mbps minimal bandwidth, or 1e−6 bit error rate, the system became unsafe to use. For example, ventilator waveforms visualized on the remote-control application demonstrated freezes, out-of-synchronization, and moving backwards; and the connection between the ventilator and the remote-control application became unstable. Conclusion The presented test methods confirmed the robustness of the NKV-550 ventilator against high-frequency and erroneous remote control, quantified the impact of network disruptions on the usability, reliability, and safety of the NK-DocBox system and identified the minimum network QoS requirements for it to function safely. These generalizable test methods can be customized to evaluate other remote ventilator control technologies and remote control of other types of medical devices against communication failures and network disruptions.

Funder

Medical Technology Enterprise Consortium

MITRE

Publisher

Oxford University Press (OUP)

Reference16 articles.

1. The eICU: it’s not just telemedicine;Celi;Crit Care Med,2001

2. Remote-controlled hospital devices get COVID-19 guidance;Association for the Advancement of Medical Instrumentation (AAMI),2020

3. NKV-550 Series Ventilator System;Nihon Kohden

4. Preventing infectious diseases in intensive care unit by medical devices remote control: lessons from COVID-19;Garzotto;J Crit Care,2021

5. Enforcement policy for ventilators and accessories and other respiratory devices during the Coronavirus Disease 2019 (COVID-19), Public health emergency guidance for industry and Food and Drug Administration staff;U.S. Food and Drug Administration

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3