The Effect of Simulated Field Storage Conditions on Dental Restorative Materials for Military Field Use

Author:

Lemon David J1,Chen Wen1,Smith Trevor1,Ford April A1,Moffett Steven X1,Hoyle Jeffrey T1,Hamlin Nicholas J1,Hwang Yoon Y1

Affiliation:

1. Naval Medical Research Unit San Antonio, 3650 Chambers Pass, Bldg 3610, JBSA Fort Sam Houston, TX, 78234

Abstract

Abstract Introduction Dental readiness, one critical component of medical readiness, is adversely impacted by dental emergencies. Many dental emergencies require restorative materials such as glass ionomers, resins, and zinc oxide eugenols to remedy them. The Authorized Dental Allowance List (ADAL) and Authorized Medical Allowance List (AMAL) contain the equipment and materials used by Navy dentists to treat Sailors and Marines. These supplies are subjected to harsh storage conditions on deployments. Much is known about how materials behave when stored at room temperature, but less is known about how their properties are affected after exposure to high temperatures and humidity. We subjected five dental restorative materials to storage in aggravated conditions, and then tested them to determine which products are more robust. Materials and Methods Unopened packages of Fuji Triage, Fuji IX GP (both GC America Inc., Alsip, Illinois), TPH Spectra ST Low Viscosity, Intermediate Restorative Material (both Dentsply Sirona, York, Pennsylvania), and Herculite XRV (Kerr Corporation, Orange, California) were exposed to 0, 5, or 10 days’ storage at 30–60°C with 95% relative humidity. After storage in these aggravated conditions, we tested the compressive strength, hardness, elastic modulus, flexural strength, flexural modulus, sorption, and solubility of each material. Results The physical properties of all materials were affected by storage in aggravated conditions, though the properties of some materials degraded more than others. Both glass ionomers, Fuji Triage (P = 0.0012) and Fuji IX GP (P = 0.0031), and the composite Herculite XRV (P = 0.0253) lost compressive strength after 5 or 10 days in aggravated conditions. The hardness values for all materials were affected (P < 0.05) by the aggravated conditions, though the elastic modulus of TPH Spectra was not affected (P > 0.05). None of the materials lost flexural strength (P > 0.05) or had changes in their flexural modulus (P > 0.05). The water sorption behavior of Fuji Triage (P = 0.0426) and Fuji IX GP (P = 0.0201) changed after 10 days of aggravated storage, and the solubility of all materials was altered by the harsh conditions. Conclusion Some materials degrade more than others in aggravated conditions. Both resin composite materials were more resistant to high temperatures and humidity levels than the glass ionomers tested. These changes in physical characteristics should be considered when reviewing or optimizing the ADAL/AMAL for different projected operational environments.

Funder

Naval Medical Research Center’s Advanced Medical Development Program

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3