Reliability of Continuous Noninvasive Hemoglobin Monitoring in Healthy Participants During En Route Care Training

Author:

Davis William T123,Valdez-Delgado Krystal K1,Bennett Christopher1,Mann-Salinas Elizabeth1ORCID,Burnett Gregory M4,Bedford Theresa4,Albright-Trainer Brooke56,Savell Shelia C1ORCID,Sorensen Derek4

Affiliation:

1. En route Care Research Center/59 MDW/ST, Defense Health Agency , Sam Houston, TX 78234, USA

2. Department of Emergency Medicine, Brooke Army Medical Center , Fort Sam Houston, TX 78234, USA

3. Department of Military and Emergency Medicine, Uniformed Services University , Bethesda, MD 20814, USA

4. Air Force Research Laboratory, 711 Human Performance Wing , Wright-Patterson AFB, OH 45433, USA

5. Department of Anesthesiology, VCU Health , Richmond, VA 23249, USA

6. Central VA Health Care System , Richmond, VA 23249, USA

Abstract

ABSTRACT Introduction Current standards for hemoglobin monitoring during air transports of U.S. combat wounded are invasive and intermittent. Fielded pulse co-oximeters can noninvasively measure total hemoglobin, but this parameter is not currently utilized. The primary objective of this study was to assess the percentage of vital sign measurements with successful capture of total noninvasive hemoglobin measurement using spectrophotometry-based technology for Hb (SpHb) measurements in healthy participants during training flights. Secondary objectives were to assess the feasibility of a novel electronic data capture mechanism from usual patient movement items and perform a pilot analysis of SpHb changes in healthy participants during transitions from ground to air transport. Methods We conducted a feasibility study enrolling healthy participants who had hemodynamic monitoring during usual U.S. Air Force Critical Care Air Transport (CCAT) flight training exercises from 2022 to 2023. Usual CCAT monitoring equipment and currently used Masimo Rainbow® pulse co-oximeters had the capability to measure SpHb. After each training exercise, the study team wirelessly downloaded case files from patient monitors utilizing the Battlefield Assisted Trauma Distributed Observation Kit (BATDOKTM) Case Downloader application. We then calculated point and precision estimates for the percentage of time for successful SpHb capture during the exercise and compared this to pulse oximetry (SpO2) capture. An a priori precision analysis for percentage of flight-time with successful SpHb data capture and descriptive statistics were performed. This study received Exempt Determination by the 59th Medical Wing IRB. Results We analyzed 26 records with mean monitoring durations of 94.5 [59.3-119.9] minutes during ground phases and 78.0 [59.9-106.5] minutes during flight phases. SpHb measures were successfully captured for 97.7% (n = 4,620) of possible ground measurements and 97.2% (n = 3,973) of possible in-flight measurements compared to 99.5% ground and 98.2% in-flight capture for SpO2. Mean intervals of missing SpHb data were 2 ± 5 minutes on the ground and 4 ± 6 minutes in-flight. Mean SpHb increased by 0.93 ± 0.96 g/dL during the ground phase, but had minimal changes during ascent, cruising altitude or descent. The BATDOKTM Case downloader completed transfer for all files. Conclusion Masimo Rainbow® SpHb pulse co-oximeters reliably captured continuous, noninvasive hemoglobin measurements using usual CCAT patient movement items in healthy participants during both ground and flight training. The BATDOKTM Case Downloader successfully imported case files from CCAT patient monitors. Mean SpHb measures had a small increase during the ground phase of monitoring followed by minimal changes when transitioning to flight altitude.

Funder

U.S. Air Force

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3