A Deployable Viscoelastic Coagulation Monitor Enables Point-of-Care Assessment of Coagulopathy in Swine With Polytrauma

Author:

Roberts Teryn R1ORCID,Garcia Isabella1,Slychko Ivan2,Dalton Heidi J3,Batchinsky Andriy I1

Affiliation:

1. Autonomous Reanimation and Evacuation Research Institute, The Geneva Foundation , San Antonio, TX 78235, USA

2. Shupyk National Healthcare University of Ukraine , Kyiv, Ukraine 04112, USA

3. Creighton University , Phoenix, AZ 85012, USA

Abstract

ABSTRACT Introduction Absence of pre-hospital coagulation tests challenges prompt management of hemostasis after trauma. The Viscoelastic Coagulation Monitor (VCM, Entegrion, Durham, NC) is a hand-held coagulation test for point-of-care. We evaluated VCM in a translational swine polytrauma model, hypothesizing that VCM correlates with a laboratory reference method, the TEG 5000 (Haemonetics, Boston, MA), and can identify coagulopathic phenotypes relevant to trauma. Our secondary hypothesis was that pre-warming of VCM disposable test cartridges using a heating plate versus pre-warming of cartridges by carrying the cartridge in the user’s pocket does not significantly alter results. Materials and Methods This study was conducted in tandem with a parent study involving anesthetized, mechanically ventilated swine (n = 20; 54 ± 5 kg) that encountered traumatic brain injury, pulmonary contusion and hemorrhage, or combination/polytrauma injury. Blood was collected at baseline, post-injury, post-shock, post-transfusion, and 6-, 24-, and 48 h post-injury to perform VCM at point-of-care. Within-group effect of time was assessed. Spearman correlation examined linear relations between VCM and standard laboratory-based coagulation tests; as well as lactate, ionized calcium, and body temperature. Logistic regression examined predictiveness of VCM to identify coagulopathic phenotypes, with receiver operator characteristic curves generated to assess diagnostic capability. At a subset of timepoints, necessity of pre-warming the VCM test cartridge using a heating plate versus pre-warming the cartridge by placement in the user’s pocket was assessed by conducting simultaneous tests on two separate instruments, with results analyzed by paired t-test with crossover design. Results VCM revealed time-dependent changes in clotting time, clot formation time (CFT), alpha, maximum clot firmness (MCF), and lysis index (LI30). All VCM metrics correlated with the respective TEG 5000 metrics, with strongest correlation for VCM MCF with TEG MA (rhos = 0.77, P < .0001) and VCM LI30 with TEG LY30 (rhos = −0.76, P < .0001). VCM demonstrated good (area under the curve >0.70) to excellent (area under the curve >0.90) diagnostic accuracy in detection of low platelet count (MCF), low hematocrit (clotting time, clot formation time, alpha, and MCF), low fibrinogen (MCF), and high fibrinogen (alpha, MCF). There was no statistically or clinically relevant effect of cartridge warming method on results. Conclusions In a trauma model, VCM detected significant changes in coagulation at point-of-care in a simplified portable form factor. VCM could enable informed hemostasis management in pre-hospital settings where coagulations tests are unavailable, pending further validation in clinical trials.

Funder

Congressionally Directed Medical Research Programs

Publisher

Oxford University Press (OUP)

Reference32 articles.

1. Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations;Kauvar;J Trauma Acute Care,2006

2. Trauma-induced coagulopathy;Moore;Nature Reviews Disease Primers,2021

3. Died of wounds on the battlefield: causation and implications for improving combat casualty care;Eastridge;J Trauma,2011

4. Outcomes of traumatic hemorrhagic shock and the epidemiology of preventable death from injury;Eastridge;Transfusion,2019

5. Hyperfibrinolysis, physiologic fibrinolysis, and fibrinolysis shutdown: the spectrum of postinjury fibrinolysis and relevance to antifibrinolytic therapy;Moore;J Trauma Acute Care Surg,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3