Lower Neck Injury Assessment Risk Curves Based on Matched-Pair Human Data for Anthropomorphic Test Devices

Author:

Humm John1,Yoganandan Narayan1

Affiliation:

1. Center for NeuroTrauma Research, Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, 53226, USA

Abstract

ABSTRACT Introduction Under G +x accelerative loading, the Hybrid III anthropomorphic test device (ATD) is used to advance human safety. Although injury assessment risk curves (IARCs) are available at the level of the occipital condyles (commonly termed as upper neck), they do not exist for the cervical-thoracic junction (lower neck). The objectives of this study are to develop IARCs under G +x impact accelerations for the Hybrid III ATD and test device for human occupant restraint (THOR) ATD at the cervical thoracic junction. Methods A series of Hybrid III ATD tests were conducted using input conditions that matched previously published cadaver tests. A separate series of THOR-ATD tests were conducted using the same input conditions that matched the same previously published cadaver tests. This type of experimental design where the cadaver input condition is the same as the ATD tests are termed matched-pair tests (Cadaver-Hybrid III and Cadaver-THOR-ATD). Injury outcomes from human cadaver tests were used with loads at the cervical thoracic junction, measured in the ATD tests. Data were censored based on injury outcomes and the number of tests conducted on each specimen. Parametric survival analysis was used to derive IARCs for cervical thoracic junction force-, moment-, and interaction-based lower neck injury criterion (LNic). Results Injuries were scored according to the Abbreviated Injury Scale scheme. Abbreviated Injury Scale 1 or 2 was scored as injured. The 50% risk levels for the Hybrid III ATD were 315 N, 70 Nm, and 1.12 for the cervical thoracic A/P shear force-, sagittal plane extension moment-, and LNic-based injury criterion, respectively. Results for the THOR ATD were 261 N, 69 Nm, and 1.51. Conclusions This is the first study to develop cervical thoracic junction IARCs for the ATDs based on force, moment, and LNic for posterior to anterior loading.

Funder

Office of the Assistant Secretary of Defense for Health Affairs

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,General Medicine

Reference22 articles.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3