High relative reliability and responsiveness of the forgotten joint score-12 in patients with femoroacetabular impingement undergoing hip arthroscopic treatment. A prospective survey-based study

Author:

Bramming Ida Birgitte1,Kierkegaard Signe2,Lund Bent2,Jakobsen Stig S3,Mechlenburg Inger34

Affiliation:

1. Department of Sports Science and Clinical Biomechanics, Faculty of Health Sciences, University of Southern Denmark, Denmark

2. Department of Orthopaedic Surgery, Horsens Regional Hospital, Denmark

3. Department of Orthopaedic Surgery, Aarhus University Hospital, Denmark

4. Department of Clinical Medicine, Centre of Research in Rehabilitation (CORIR), Aarhus University Hospital and Aarhus University, Denmark

Abstract

Abstract The forgotten joint score-12 (FJS-12) may be an advantageous questionnaire in young patients with high hip function and a low level of pain. We investigated the reliability and the responsiveness of the FJS-12 in patients with femoroacetabular impingement undergoing hip arthroscopic treatment. Fifty patients were included in the reliability study and 34 patients were included in the responsiveness study. Test–retest reliability was assessed with intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC). Responsiveness was assessed from testing correlations between the FJS-12 and the Copenhagen Hip and Groin Outcome Score (HAGOS) of the change score, effect size (ES) and standardized response mean (SRM). Floor and ceiling effect were defined as present if the number of patients obtaining the maximum (100) and minimum score (0) exceeded 15%. The relative reliability was high (ICC = 0.9, 95% CI: 0.8–0.9) and the absolute reliability was low (SEM = 11, MDCindividual = 32, MDCgroup = 4.5). The responsiveness was high, and the change score was highly correlated with the subscale ‘pain’ from the HAGOS and moderately correlated with the subscale ‘ADL’. Furthermore, the FJS-12 exceeded or equalled the HAGOS subscales in ES and SRM. Below 15% of the patients scored the maximum or minimum score. The FJS-12 has high reliability, high responsiveness to change and shows no floor or ceiling effect.

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

Reference29 articles.

1. Guidance for industry: patient-reported outcome measures: use in medical product development to support labeling claims: draft guidance;Health Qual Life Outcomes,2006

2. Spørg brugerne – en guide til kvalitative og kvantitative brugerundersøgelser i sundhedsvæsenet;Gut;Enheden for Brugerundersøgelser, Region Hovedstaden,2011

3. The “forgotten joint” as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure;Behrend;J Arthroplasty,2012

4. Joint awareness in osteoarthritis of the hip and knee evaluated with the ‘forgotten joint’ score before and after joint replacement;Thienpont;Knee Surg Sports Traumatol Arthrosc,2016

5. Comparative responsiveness of outcome measures for total knee arthroplasty;Giesinger;Osteoarthritis Cartilage,2014