Cystatin C kidney functional reserve: a simple method to predict outcome in chronic kidney disease

Author:

Christiadi Daniel12ORCID,Simpson Charles2,O’brien Kate3,Taylor Kylie12,Luxton Grant12,Rossleigh Monica4,Erlich Jonathan12,Endre Zoltán H12

Affiliation:

1. Department of Nephrology, Prince of Wales Hospital, Randwick, NSW, Australia

2. Faculty of Medicine, University of New South Wales, Kensington, NSW, Australia

3. Nutrition and Dietetics Services, Prince of Wales Hospital, Randwick, NSW, Australia

4. Department of Nuclear Medicine, Prince of Wales Hospital, Randwick, NSW, Australia

Abstract

Abstract Background Kidney functional reserve (KFR), the only clinical kidney stress test, is not routinely measured because the complexity of measurement has limited clinical application. We investigated the utility of plasma cystatin C (CysC) after oral protein loading (PL) to determine KFR in Stages 3 and 4 chronic kidney disease (CKD). Methods Following a 24-h low-protein diet, KFR was measured after oral protein by hourly plasma CysC and compared with simultaneous creatinine clearance (CrCl) and radionuclide 99technetium diethylenetriaminepentaacetatic acid (Tc-99m-DTPA) measured glomerular filtration rate (mGFR) measurement in an observational, single-centre cohort study of adults with CKD Stages 3 and 4. Subjects were followed for 3 years for fast (F) or slow (S) CKD progression, dialysis requirement or death or a combination of major adverse kidney events (MAKEs). Result CysC, CrCl and Tc-99m-DTPA mGFR measurements of KFR in 19 CKD Stage 3 and 21 CKD Stage 4 patients yielded good agreement. KFR was not correlated with baseline kidney function. Eight CKD Stage 3 (42%) and 11 CKD Stage 4 (52%) subjects reached their lowest serum CysC concentration 4 h after PL. CysC KFR and baseline serum creatinine (sCr) predicted death or dialysis or MAKE-F with a respective area under the curve (AUC)  of 0.73 [95% confidence interval (CI) 0.48–0.89] and 0.71 (95% CI 0.51–0.84). Including CysC KFR, age, baseline sCr and nadir CysC predicted a decrease in sCr-estimated GFR >1.2 mL/min/year (MAKE-S) with an AUC of 0.89. Conclusions Serial CysC avoided timed urine collection and radionuclide exposure and yielded equivalent estimates of KFR. Serial CysC may facilitate monitoring of KFR in clinical practice.

Funder

Australian Kidney Biomarker Reference Laboratory from the Prince of Wales Hospital Foundation

Publisher

Oxford University Press (OUP)

Subject

Transplantation,Nephrology

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别