Management of Mammographic Architectural Distortion Based on Contrast-enhanced MRI and US Correlation

Author:

DiPrete Olivia1ORCID,Wei Catherine J2,Phillips Jordana3,Fishman Michael D C3ORCID,Slanetz Priscilla J3,Lotfi Parisa4,Brook Alexander1,Dialani Vandana1ORCID

Affiliation:

1. Beth Israel Deaconess Medical Center, Department of Radiology , Boston, MA , USA

2. Mass General Brigham – Salem Hospital, Department of Radiology , Salem, MA , USA

3. Boston Medical Center, Department of Radiology , Boston, MA , USA

4. Danbury Radiological Associates, Department of Radiology , Danbury, CT , USA

Abstract

Abstract Objective The objective was to evaluate outcomes of mammographic architectural distortion (AD) with and without MRI and US correlates. Methods A retrospective review of unexplained mammographic AD with subsequent MRI from January 1, 2007 to September 30, 2017 was performed using a reader-based study design. Mammographic, MRI, and US features and outcomes were documented. Truth was based on biopsy results or minimum two-year imaging follow-up. Measures of diagnostic accuracy were calculated. Results Fifty-six cases of AD were included: 29 (51.8%) detected on 2D mammogram and 27 (48.2%) detected on digital breast tomosynthesis. Of 35.7% (20/56) with MRI correlate, 40.0% (8/20) were enhancing masses, 55.0% (11/20) were non-mass enhancement (NME), and 5.0% (1/20) were nonenhancing AD. Of eight enhancing masses, 75.0% (6/8) were invasive cancers, and 25.0% (2/8) were high-risk lesions. Of 11 NME, 18.2% (2/11) were ductal carcinoma in situ, 36.4% (4/11) were high-risk lesions, and 45.4% (5/11) were benign. Of 64.3% (36/56) without MRI correlate, 94.4% (34/36) were benign by pathology or follow-up, one (2.8%, 1/36) was a 4-mm focus of invasive cancer with US correlate, and one (1/36, 2.8%) was a high-risk lesion. Of cases without MRI and US correlates, one (3.0%, 1/33) was a high-risk lesion and 97.0% (32/33) were benign. The negative predictive value of mammographic AD without MRI correlate was 97.2% (35/36) and without both MRI and US correlates was 100.0% (33/33). Conclusion Mammographic AD without MRI or US correlate was not cancer in our small cohort and follow-up could be considered, reducing interventions.

Funder

GE Healthcare

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3