Development of an opportunistic diagnostic prediction algorithm for osteoporosis and fragility fracture risk estimates from forearm radiographs (The OFFER1 Study)

Author:

Meertens Robert1,Lopez Ben2,Crone Ben2,Gundry Mike1,Metcalfe-Smith Emma2,Gibbard Warren2,Jubb Thomas2,Manning Fay1,Scott Paul2,McWilliam Richard2

Affiliation:

1. University of Exeter , Medical Imaging Exeter, EX1 2LU , United Kingdom

2. Ibex Innovations Ltd. , Sedgefield, TS21 3FD , United Kingdom

Abstract

Abstract Osteoporosis and associated fractures are an increasingly prevalent concern with an ageing population. This study reports testing of IBEX Bone Health (IBEX BH) software, applied following acquisition of forearm radiographs. IBEX Bone Health analyses the radiograph to measure areal bone mineral density (aBMD) at the examination site. A non-randomized cross-sectional study design was performed involving 261 (254 after exclusions) participants (112/142 m/f; mean age 70.8 years (SD+/–9.0); 53 with osteoporosis). They underwent posterior–anterior distal forearm radiographs; dual X-ray absorptiometry (DXA) of the wrists, hips, and lumbar spine; and questionnaires exploring clinical risk factors. IBEX Bone Health automatically identifies regions of interest (ROI) at the ultra-distal (UD) and distal third (TD) regions of the radius. Analysis investigated area under the receiver operating characteristics curve performance of IBEX BH for prediction of (i) osteoporosis (based on clinical reporting of the hip and spine DXA) and (ii) treatment recommendations by Fracture Risk Assessment Tool (FRAX) inclusive of neck of femur (NoF) areal bone mineral density (aBMD) results following National Osteoporosis Guideline Group (NOGG) guidelines. Area under the receiver operating characteristics curve for osteoporosis prediction at the UD and TD ROIs were 0.86 (99% confidence interval (CI) [0.80, 0.91]) and 0.81 (99% CI [0.75, 0.88]), respectively. Area under the receiver operating characteristics curve for treatment recommendation using FRAX inclusive of NoF aBMD at the UD and TD ROIs were 0.95 (99% CI [0.91, 1.00]) and 0.97 (99% CI [0.93,1.00]), respectively. With a matched sensitivity to FRAX (without NoF aBMD) 0.93 (99% CI [0.78, 0.99]), IBEX BH predicted at the UD and TD ROIs recommended treatment outcomes by NOGG guidelines using FRAX (with NoF aBMD) with specificity 0.89 (99% CI 0.83, 0.94]) and 0.93 (99% CI [0.87, 0.97]), respectively. This is compared with 0.60 (99% CI [0.51, 0.69]) for FRAX (without NoF aBMD). Results demonstrate the potential clinical utility of IBEX BH as an opportunistic screening tool.

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3