Evaluation of methods to eliminate analytical interference in multiple myeloma patients with spurious hyperphosphatemia

Author:

Tian Xin1,Zhao Li1,Ma Jin1,Lu Jie1,Zhu Tian-yi1,Liu Yan1,Sun Hong-xun1

Affiliation:

1. Department of Laboratory Medicine, The Third Hospital of Hebei Medical University , Shijiazhuang , China

Abstract

Abstract Objective The acid/molybdate assay performed on the Beckman Coulter AU5821 could be subject to paraprotein interference, which potentially results in spurious hyperphosphatemia. We attempted to find a reliable solution to eliminate paraprotein interference in laboratory test results and discuss the causes of paraprotein interference. Methods We observed 50 multiple myeloma patients with serum paraproteins. We used the trichloroacetic acid (TCA) deproteinizing method to confirm that paraproteins indeed interfered with phosphate detection in the serum acid/molybdate assay. Furthermore, we used the dry chemical method (Vitros 5.1 FS, Johnson) and deionized water (H2O), normal saline (NS), and healthy human serum as alternative diluents. We assessed the clinical acceptability of the 4 methods by evaluating a bias percentage (bias%) lower than 10% under the premise of TCA treatment as a serum phosphate reference method. Results In total, comparing the results of the TCA treatment on the Beckman Coulter AU5821, 3/50 (6%) multiple myeloma patients exhibited phosphate pseudo-elevation (bias% >10%). Additionally, we found pseudo-hypophosphate only in immunoglobulin (Ig)G-kappa paraprotein samples, and all were above 50 g/L. The bias% between TCA and dry chemical method for the 3 patients was below 10%. The maximum acceptable dilutions for patient 22 were 8-fold H2O, 4-fold H2O , and 2-fold serum; those for patient 45 were 16-fold H2O, 16-fold H2O, and 2-fold serum. However, the bias% of patient 40 was beyond the acceptable range in all 3 dilution groups. Conclusion High concentrations of IgG kappa–type paraproteins are more likely to interfere with serum phosphorous detection. Both the TCA and dry chemical method can effectively eliminate paraprotein interference.

Funder

Health Commission of Hebei Province

Hebei Education Department

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Reference15 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3