Evaluation of PTV margin in CBCT-based online adaptive radiation therapy for gastric mucosa-associated lymphoid tissue lymphoma

Author:

Hirose Taka-aki12,Takaki Masanori34,Shibayama Yusuke12,Fukunaga Jun-ichi12,Kato Toyoyuki12,Yoshitake Tadamasa34,Ishigami Kousei34

Affiliation:

1. Division of Radiology , Department of Medical Technology, , 3-1-1 Maidashi, Higashi-Ku, Fukuoka 812-8582 , Japan

2. Kyushu University Hospital , Department of Medical Technology, , 3-1-1 Maidashi, Higashi-Ku, Fukuoka 812-8582 , Japan

3. Department of Clinical Radiology , Graduate School of Medical Sciences, , 3-1-1 Maidashi, Higashi-Ku, Fukuoka 812-8582 , Japan

4. Kyushu University , Graduate School of Medical Sciences, , 3-1-1 Maidashi, Higashi-Ku, Fukuoka 812-8582 , Japan

Abstract

Abstract The aim of this study was to investigate planning target volume (PTV) margin in online adaptive radiation therapy (oART) for gastric mucosa-associated lymphoid tissue (MALT) lymphomas. Four consecutive patients with gastric MALT lymphoma who received oART (30 Gy in 15 fractions) on the oART system were included in this study. One hundred and twenty cone-beam computed tomography (CBCT) scans acquired pre- and post-treatment of 60 fractions for all patients were used to evaluate intra- and interfractional motions. Patients were instructed on breath-holding at exhalation during image acquisition. To assess the intrafraction gastric motion, different PTVs were created by isotropically extending the CTV contoured on a pre-CBCT image (CTVpre) at1 mm intervals. Intrafraction motion was defined as the amount of expansion covering the contoured CTV on post-CBCT images (CTVpost). Interfractional motion was defined as the amount of reference CTV expansion that could cover each CTVpre, as well as the evaluation of the intrafractional motion. PTV margins were estimated from the cumulative proportion of fraction covering the intra- and interfractional motions. The extent of expansion covering the CTVs in 90% of fractions was adopted as the PTV margin. The PTV margin for intrafractional gastric motion using the oART system with breath-holding was 14 mm. In contrast, the PTV margin for interfractional gastric organ motion without the oART system was 25 mm. These results indicated that the oART system can reduce the PTV margin by >10 mm. Our results could be valuable data for oART cases.

Funder

JSPS KAKENHI

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3