Diagnostic Reference Levels for Common CT Examinations: Results from a Statewide dose Survey

Author:

Jusoh Irwan Iskandar1,Abdullah Kamarul Amin1ORCID,Ali Mohd Hanafi2

Affiliation:

1. School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin , Kuala Nerus, Terengganu 21300 , Malaysia

2. Sydney School of Health Sciences, Faculty of Medicine and Health, Level 7, University of Sydney Discipline of Medical Imaging Science, , D18 Susan Wakil Health Building, Western Avenue, Camperdown, NSW 2006 , Australia

Abstract

Abstract The aim of this study was to investigate the current radiation doses for CT examinations throughout a state in Malaysia and, based on this data, to propose local diagnostic reference levels (DRLs) for the most common CT examinations. A study was conducted in three of the four hospitals that have provided CT services throughout the state. A survey booklet was designed to facilitate collection of pertinent CT scan data. The following information were extracted and recorded for each study: tube voltage, tube current, number of scans phases, CT dose index volume (CTDIvol) and dose length product (DLP). Proposed local DRLs of CT brain and thorax were up to 12% lower than the current national DRLs. However, an increase of DLP (median value) for CT abdomen was also found as compared to the 75th percentile of national DRLs. Therefore, considerable optimisation should be made to achieve a better dose reduction.

Funder

UFRGS

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference30 articles.

1. CT is still not a low-dose imaging modality;Rehani;Med. Phys.,2020

2. Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: a systematic review;Abdullah;J. Med. Imaging Radiat. Oncol.,2016

3. A review of the fundamental principles of radiation protection when applied to the patient in diagnostic radiology;Moores;Radiat. Prot. Dosim.,2017

4. Techniques and applications of automatic tube current modulation for CT;Kalra;Radiology,2004

5. Radiological protection and safety in medicine;ICRP;Ann. ICRP,1996

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3