Deceived by the Fick principle: blood flow distribution in heart failure

Author:

Agostoni Piergiuseppe12ORCID,Cattadori Gaia23,Vignati Carlo12,Apostolo Anna1ORCID,Farina Stefania1,Salvioni Elisabetta1,Di Marco Silvia3,Sonaglioni Andrea3,Nodari Savina4,Marenzi Giancarlo1,Schmidt-Trucksäss Arno5,Myers Jonathan6

Affiliation:

1. Centro Cardiologico Monzino, IRCCS , Via Parea, 4, 20138 Milan , Italy

2. Department of Clinical Sciences and Community Health, Cardiovascular Section, University of Milano , Via Parea, 4, 20138 Milan , Italy

3. Multimedica IRCCS , Milan , Italy

4. Department of Medical and Surgical Specialities, Radiological Sciences and Public Health, University of Brescia Medical School , Brescia , Italy

5. Division of Sport and Exercise Medicine, Department of Sport, Exercise and Health, University of Basel , Birsstrasse 320B, CH-4052 Basel , Switzerland

6. Cardiology Division, VA Palo Alto Health Care System and Stanford University , Palo Alto, CA , USA

Abstract

Abstract Aims The Fick principle states that oxygen uptake (V̇O2) is cardiac output (Qc) * arterial-venous O2 content difference [ΔC(a-v)O2]. Blood flow distribution is hidden in Fick principle, and its relevance during exercise in heart failure (HF) is undefined. To highlight the role of blood flow distribution, we evaluated peak exercise V̇O2, Qc, and ΔC(a-v)O2, before and after HF therapeutic interventions. Methods and results Symptom-limited cardiopulmonary exercise tests with Qc measurement (inert gas rebreathing) was performed in 234 HF patients before and 6 months after successful exercise training, cardiac resynchronization therapy, or percutaneous edge-to-edge mitral valve repair. Considering all tests (n = 468), a direct correlation between peakV̇O2 and peakQc (R2 = 0.47) and workload (R2 = 0.70) was observed. Patients were grouped according to treatment efficacy in Group 1 (peakV̇O2 increase >10%, n = 93), Group 2 (peakV̇O2 change between 0 and 10%, n = 60), and Group 3 (reduction in peakV̇O2, n = 81). Post-treatment peakV̇O2 changes poorly correlated with peakQc and peakΔC(a-v)O2 changes. Differently, post-procedure peakQc vs. peakΔC(a-v)O2 changes showed a close negative correlation (R2 = 0.46), becoming stronger grouping patients according to peakV̇O2 improvement (R2 = 0.64, 0.79, and 0.58 in Groups 1, 2, and 3, respectively). In 76% of patients, peakQc and ΔC(a-v)O2 changes diverged regardless of treatment. Conclusion The bulk of these data suggests that blood flow distribution plays a pivotal role on peakV̇O2 determination regardless of HF treatment strategies. Accordingly, for assessing HF treatment efficacy on exercise performance, the sole peakV̇O2 may be deceptive and the combination of V̇O2, Qc and ΔC(a-v)O2, must be considered.

Funder

Italian Ministry of Health

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3