The influence of aircraft noise exposure on the systemic and renal haemodynamics

Author:

Bosch AgnesORCID,Kannenkeril Dennis1,Jung Susanne12,Striepe Kristina1,Karg Marina V1,Ott Christian13,Schmieder Roland E1ORCID

Affiliation:

1. Department of Nephrology and Hypertension, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054 Erlangen, Germany

2. Department of Cardiology, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054 Erlangen, Germany

3. Department of Nephrology and Hypertension, Paracelsus Medical School, Nuremberg, Germany

Abstract

Abstract Aims Epidemiological studies found a link between aircraft noise exposure and increased incidence of arterial hypertension and cardiovascular disease, but the underlying pathophysiological mechanisms are not fully understood. Clinical studies have shown that mental stress affects the systemic and renal haemodynamic, but no such study was performed with noise exposure as stress factor. We analysed systemic and renal effects of 25 min standardized aircraft noise in a sham controlled clinical study including 80 healthy men and 34 male patients with hypertension. Methods and results Systemic haemodynamic parameters were measured using electrocardiography and impedance cardiography. The renal haemodynamic was assessed using steady state input clearance with infusion of para-aminohippuric acid and inulin for glomerular filtration rate and renal plasma flow, respectively. In the systemic circulation of hypertensive patients, there was an increase in total peripheral resistance (TPR) (1420 ± 387 vs. 1640 ± 516 dyn·s·cm−5, P = 0.001) and a decrease in cardiac index (CI) (2.9 ± 0.8 vs. 2.6 ± 0.8 L/(min·m2, P < 0.001) 25 min after the start of noise exposure, which was not present during sham procedure (P = 0.10, P = 0.86). In healthy individuals a procedure induced increase in TPR and decrease in CI was present after noise (TPR: 995 ± 239 vs. 1106 ± 308 dyn·s·cm−5, P = 0.001, CI: 3.6 ± 0.7 vs. 3.3 ± 0.9 L/(min·m2, P < 0.001) and sham application (TPR: P = 0.002, CI: P < 0.001). However, in healthy individuals changes in TPR (P = 0.450) and CI (P = 0.605) from baseline until 25 min after the start of the intervention did not differ between noise and sham exposure. In the renal circulation of hypertensive patients and healthy individuals the response did not differ between noise and sham procedure. Conclusions In hypertensive but not healthy men we observed a systemic vasoconstrictive response after aircraft noise exposure accompanied by a decrease in CI. No significant changes were observed in the renal circulation. Our results suggest that male hypertensive patients are more susceptible for noise-induced changes of vascular resistance in the systemic circulation.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Epidemiology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3