Study on low temperature phase change heat storage and its performance of solar and air source heat pump system

Author:

Zhan Hao1,Wu Ronghua12ORCID,Yu Hao2,Liu Changqing1,Li Kang2

Affiliation:

1. Qingdao University College of Mechanical and Electrical Engineering, , No. 308 Ningxia Road, Shinan District, Qingdao, Shandong 266071, China

2. Qingdao Kechuang Blue New Energy Co., LTD. , No. 7, Kechuang Road, Jiaobei Town, Jiaozhou City, Qingdao, Shandong 266300, China

Abstract

Abstract In view of the deterioration of the performance of air source heat pump at low temperature in cold regions and the large fluctuation of solar heating systems, a heat pump system with low-temperature heat storage using sodium chloride aqueous solution as the phase change thermal storage material is proposed. The system form and its operation scheme, unit energy consumption model and economic evaluation index are given. The influence of different concentrations of sodium chloride solution corresponding to different heat storage temperatures and different areas of solar collectors on the system operation economy is studied, and simulation analysis and optimization are carried out and the operation efficiency and operation economy of the system are analyzed with an actual residential building in a cold region as an example. The results show that with the increase of collector area, the lower the sodium chloride concentration, the higher the heat storage temperature and the higher the coefficient of performance (COP) of the system; the larger the collector area, the higher the COP of the system, but the payback period decreases first and then extends with the increase of the collector area. When the system sodium chloride solution concentration is 5.3% and the collector area is 372m2, there is a minimum payback period for the winter heating of 3000m2 building in this case, and at this time, the COP of the system is 2.37, which is 20% higher than that of the traditional air source heat pump. The payback period of the system is 7.7 years, and the contribution rate of the solar collector system is 53%. The solar air source heat pump system with low temperature phase change heat storage significantly improves the operation performance of the system and has good energy saving benefits.

Publisher

Oxford University Press (OUP)

Subject

General Environmental Science,Architecture,Civil and Structural Engineering

Reference26 articles.

1. Techno-economic analysis of air source heat pump applied for space heating in northern China;Zhang;Appl Energy,2017

2. Feasibility and performance study on hybrid air source heat pump system for ultra-low energy building in severe cold region of China;Xu;Renew Energy,2020

3. Recent progress in solar water heaters and solar collectors: a comprehensive review;Ahmed;Therm Sci Eng Prog,2021

4. Solar thermal systems: current situation and ambitious goals;Taousanidis;Nonconv Technol Rev,2020

5. A comprehensive review of solar cooker with sensible and latent heat storage materials;Panchal;Int J Ambient Energy,2019

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3