Affiliation:
1. Department of Mechnical Engineering, Dr. B. A. Technological University Lonere, Raigad, Maharashtra 402103, India
Abstract
Abstract
Thermodynamic analysis including energetic and exergetic analysis is carried out employing Engineering Equation Solver for the five modified cycles: dual expansion cycle, internal heat exchanger cycle, work recovery cycle, work recovery with internal heat exchanger cycle and vortex tube expansion cycle. Contours are developed to study the effect of gas cooler temperatures and evaporator temperatures on the system performance and optimum gas cooler pressure. The modified cycle with work recovery turbine offers relatively higher COP and higher exergetic efficiency with lower compressor discharge pressure. The exergy loss in compressor, gas cooler, throttle valve and vortex tube (VT) are considerably higher than that in internal heat exchanger (IHX), evaporator and turbine. It is observed that COP of modified cycle with VT is slightly less than that with IHX, whereas the cycle with work recovery turbine brings the highest COP with the improvement of 25% at the gas cooler exit temperature of 305 K and evaporator temperature of 248 K.
Publisher
Oxford University Press (OUP)
Subject
General Environmental Science,Architecture,Civil and Structural Engineering
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献