Intravascular haemolysis after transcatheter aortic valve implantation with self-expandable prosthesis: incidence, severity, and impact on long-term mortality

Author:

Širáková Andrea1,Toušek Petr1,Bednář František1,Línková Hana1,Laboš Marek1,Sulženko Jakub1,Havlíková Martina1,Neuberg Marek2,Kočka Viktor1

Affiliation:

1. Cardiocenter, University Hospital Královské Vinohrady and 3rd Faculty of Medicine, Charles University, Ruská 87, Prague 10 100 00, Czech Republic

2. Medtronic Czechia, Czech Republic

Abstract

AbstractWe aimed to determine the incidence, severity, and long-term impact of intravascular haemolysis after self-expanding transcatheter aortic valve implantation (TAVI). We believe this should be evaluated before extending the indications of TAVI to younger low-risk patients. Prospective, academic, single centre study of 94 consecutive patients treated with supra-annular self-expandable TAVI prosthesis between April 2009 and January 2014. Haemolysis at 1-year post-TAVI was defined per the published criteria based on levels of haemoglobin, reticulocyte and schistocyte count, lactate dehydrogenase (LDH), and haptoglobin. All patients had long-term clinical follow-up (6 years). The incidence of haemolysis at 1-year follow-up varied between 9% and 28%, based on different haemolysis definitions. Haemolysis was mild in all cases, no patient had markedly increased LDH levels. The presence of moderate/severe paravalvular aortic regurgitation was associated with haemolysis (7.7% vs. 23.1%, P = 0.044) and aortic valve area post-TAVI did not differ between groups with or without haemolysis (1.01 vs. 0.92 cm2/m2, P = 0.23) (definition including schistocyte count). The presence of haemolysis did not have any impact on patient prognosis after 6 years with log-rank test P = 0.80. Intravascular haemolysis after TAVI with self-expandable prosthesis is present in 9–28% of patients depending on the definition of haemolysis. The presence of haemolysis is associated with moderate/severe paravalvular aortic regurgitation but not with post-TAVI aortic valve area. Haemolysis is mild with no impact on prognosis.

Funder

European Commission: Operational Programme: Research, Development, and Education

INTERCARDIS

Charles University Research Centre Program

Cardiovascular Research Program of the Charles University

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine