Effects of ventricular assist device with a fenestration in the failing Fontan circulation: a theoretical analysis using a lumped parameter model

Author:

Shimizu S1,Kotani Y2,Horio N2,Kisamori E2,Uemura K1,Kasahara S2,Shishido T1

Affiliation:

1. National Cerebral & Cardiovascular Center, Department of Research Promotion and Management , Suita , Japan

2. Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Department of Cardiovascular Surgery , Okayama , Japan

Abstract

Abstract Background Fenestration is surgically created at the time of Fontan operation, in which the extracardiac conduit is connected to the atrium through a small communication. Since the fenestration has been reported to increase venous return to the ventricle and improve the hemodynamics, the fenestration is often made when the risk of postoperative Fontan failure is high. In the failing Fontan circulation, the implantation of ventricular assist device (VAD) is sometimes required as a bridge-to-transplantation therapy. However, it has been controversial whether a closure of fenestration is necessary or not. Purpose To evaluate the effects of fenestration on the hemodynamics under VAD in the failing Fontan circulation. Methods A computational model of Fontan circulation was developed using a time-varying elastance cardiac chamber model and a modified 3-element Windkessel vasculature model. Pressure gradient through fenestration was calculated by the simplified Bernoulli’s equation. The relationship between pressure head and rotational frequency of VAD was modeled as a non-linear function. To simulate Fontan failure, ventricular end-systolic elastance was set at 1.0 mmHg/ml and then pulmonary vascular resistance index (PVRI) was varied from 3.0 to 6.8 WU m². Results In the Fontan failure model with PVRI of 3.0 WU m², mean blood pressure (MBP), cardiac index (CI) and central venous pressure (CVP) were 58.4 mmHg, 1.7 l/min/m² and 19.2 mmHg, respectively. When MBP was maintained at the same value, the 4-mm fenestration rarely affected CI (1.7 l/min/m²) and CVP (18.1 mmHg), but significantly decreased oxygen saturation (SpO2, 84.0 %). The introduction of VAD at 4000 rpm significantly increased MBP and CI in both models with/without fenestration (Fenestration (+): 93.7 mmHg, 3.2 l/min/m², Fenestration (-): 94.5 mmHg, 3.2 l/min/m²). In the model with fenestration, SpO2 recovered to 91.6 % after the VAD initiation. However, CVP slightly changed after the VAD initiation in both models with/without fenestration (18.5 and 18.9 mmHg, respectively). When stressed blood volume (SBV) was decreased until end-systolic ventricular volume became around 0 ml, CVP was decreased to the normal range (Fenestration (+): 8.3 mmHg, Fenestration (-): 10.0 mmHg). Then SBV was significantly lower in the model with fenestration than that without fenestration (-150 ml). The effects of fenestration on CVP and SBV were larger in the model with high PVRI of 6.8 WU m² (CVP: -5.5 mmHg, SBV: -460 ml) than those with PVRI of 3.0 WU m² (CVP: -1.7 mmHg, SBV: -150 ml). Conclusions Although fenestration decreases SpO2 at the onset of Fontan failure, fenestration can significantly decrease CVP and SBV under VAD support. These effects are more significant in the patients with higher PVRI. This study demonstrates that fenestration did not impair the hemodynamics under VAD support, indicating the closure of fenestration may not be necessary.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3