A Calibration Study of Therapeutic Ultrasound Units

Author:

Artho Paul A1,Thyne Jason G1,Warring Barry P1,Willis Chris D1,Brismée Jean-Michel2,Latman Neal S3

Affiliation:

1. PA Artho, PT, MPT; JG Thyne, PT, MPT; BP Warring, PT, MPT; and CD Willis, PT, MPT, were students in the Master of Physical Therapy Program, Texas Tech University Health Sciences Center, Amarillo, Tex, at the time of the study

2. JM Brismée, PT, MS, OCS, is Assistant Professor, School of Allied Health, Texas Tech University Health Sciences Center, 1400 Wallace Blvd, Amarillo, TX 79106 (USA), and Faculty Member, International Academy of Orthopaedic Medicine (IAOM-US), Tucson, Ariz.

3. NS Latman, PhD, is Associate Professor, School of Allied Health, Texas Tech University Health Sciences Center

Abstract

Abstract Background and Purpose. Physiological effects of therapeutic ultrasound (US) are dependent on the intensity and duration of application. The purpose of this study was to test US machines used in clinical settings for proper calibration of time and power output. Methods. Measurements of power output and timer accuracy were obtained from 83 US units in clinical use. The machines were tested at 4 intensity settings (0.5, 1.0, 1.5, and 2.0 W/cm2) using a continuous waveform and a 1-MHz frequency. The measured intensities were converted to percentages of error and compared with the ±20% standard. Results. Of the machines tested, 32 (39%) were outside the calibration standard for at least one output setting. Of these machines, 15 (18%) were above the +20% standard, and 17 (21%) were below the −20% standard for at least one output setting. Of the 32 machines outside the standard, 26 (31%) were outside the standard for 2 or more settings, and 3 (4%) produced no output at any of the settings. Of the mechanical timers tested, 7 (28%) were outside of the ±10% standard for timer accuracy at the 5-minute interval, and 6 (24%) were outside of the standard at the 10-minute interval. All digital timers tested were within the standard. Discussion and Conclusion. More than one third of machines tested in this study were outside the standard for power output, and approximately one fourth of the mechanical timers were outside the standard. Therefore, further improvements in the accuracy of US machine calibration are needed.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

Reference24 articles.

1. Considerations in ultrasound therapy and equipment performance;Stewart;Phys Ther,1980

2. Basic physics of therapeutic ultrasound;ter Haar;Physiotherapy,1978

3. The effect of therapeutic ultrasound on calcium uptake in fibroblasts;Mortimer;US Med Biol,1988

4. Clinical evaluation of a new approach in the treatment of contracture associated with hip fracture after internal fixation;Lehmann;Arch Phys Med Rehabil,1961

5. Effects of static stretch versus static stretch and ultrasound combined on triceps surae muscle extensibility in healthy women;Wessling;Phys Ther,1987

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3