Feasibility of frozen soft tissues to simulate fresh soft tissue conditions in cone beam CT scans

Author:

Oliveira Matheus L12ORCID,Bornstein Michael M2ORCID,Dagassan-Berndt Dorothea23ORCID

Affiliation:

1. Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas , Av. Limeira 901 , Piracicaba, SP, 13414-903, Brazil

2. Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel , Mattenstrasse 40 , Basel, 4058, Switzerland

3. Center for Dental Imaging, University Center for Dental Medicine Basel UZB, University of Basel , Mattenstrasse 40 , Basel, 4058, Switzerland

Abstract

Abstract Objectives To evaluate the feasibility of frozen soft tissues in simulating fresh soft tissues of pig mandibles using cone beam CT (CBCT). Methods Two fresh pig mandibles with soft tissues containing 2 tubes filled with a radiopaque homogeneous solution were scanned using 4 CBCT units and 2 field-of-view (FOV) sizes each. The pig mandibles were deep-frozen and scanned again. Three cross-sections were exported from each CBCT volume and grouped into pairs, with one cross-section representing a fresh and one a frozen mandible. Three radiologists compared the pairs and attributed a score to assess the relative image quality using a 5-point scale. Mean grey values and standard deviation were obtained from homogeneous areas in the tubes, compared using the Wilcoxon matched-pair signed-rank test and subjected to Pearson correlation analysis between fresh and frozen physical states (α = .05). Results Subjective evaluation revealed similarity of the CBCT image quality between fresh and frozen states. The distribution of mean grey values was similar between fresh and frozen states. Mean grey values of the frozen state in the small FOV were significantly greater than those of the fresh state (P = .037), and noise values of the frozen state in the large FOV were significantly greater than those of the fresh state (P = 0.007). Both mean grey values and noise exhibited significant and positive correlations between fresh and frozen states (P < 0.01). Conclusions The freezing of pig mandibles with soft tissues may serve as a method to prolong their usability and working time when CBCT imaging is planned.

Funder

São Paulo Research Foundation

Swiss Association of Dentomaxillofacial Radiology

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3